{"title":"Radiopharmacy","description":"","products":[{"product_id":"cardiolite-sestamibi","title":"Cardiolite Sestamibi","description":"\u003cp\u003eCardiolite\u003csup\u003e®\u003c\/sup\u003e is a technetium-labeled single photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) agent used for identifying and managing patients with known or suspected coronary artery disease (CAD) and has been used to image more than 53 million patients since 1991.\u003csup\u003e\u003ca href=\"http:\/\/www.lantheus.com\/products\/overview\/cardiolite\/#references\"\u003e1,2\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\nDESCRIPTION\n\u003cp\u003eCardiolite\u003csup\u003e®\u003c\/sup\u003e was the first technetium-labeled myocardial perfusion imaging tracer to provide physicians with prognostic information helpful in making patient management d\u003cspan\u003eecisions related to CAD.\u003c\/span\u003e\u003csup\u003e\u003ca href=\"http:\/\/www.lantheus.com\/products\/overview\/cardiolite\/#references\"\u003e1\u003c\/a\u003e\u003c\/sup\u003e\u003c\/p\u003e\nINDICATIONS \u0026amp; USAGE\n\u003cp\u003e\u003cspan\u003eMyocardial Imaging:  Cardiolite\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e (Kit for the Preparation of Technetium Tc99m Sestamibi for Injection), is a myocardial perfusion agent that is indicated for detecting coronary artery disease by localizing myocardial ischemia (reversible defects) and infarction (non-reversible defects), in evaluating myocardial function and developing information for use in patient management decisions.  Cardiolite\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e evaluation of myocardial ischemia can be accomplished with rest and cardiovascular stress techniques (e.g. exercise or pharmacologic stress in accordance with the pharmacologic stress agent’s labeling).\u003c\/span\u003e\u003c\/p\u003e\nCONTRAINDICATIONS\n\u003cp\u003e\u003cspan\u003eNone known.\u003c\/span\u003e\u003c\/p\u003e\nSAFETY INFORMATION\n\u003cp\u003eCardiolite\u003csup\u003e®\u003c\/sup\u003e has been rarely associated with acute severe allergic and anaphylactic events of angioedema and generalized urticaria.  In some patients the allergic symptoms developed on the second injection during Cardiolite\u003csup\u003e®\u003c\/sup\u003eimaging.  The most frequently reported adverse events include headache, chest pain\/angina, ST segment changes on ECG, nausea, and abnormal taste and smell.\u003c\/p\u003e\n\u003cp\u003eInfrequently, death has occurred 4 to 24 hours after Tc99m Sestamibi use and is usually associated with exercise stress testing (See Section 5.2). Pharmacologic induction of cardiovascular stress may be associated with serious adverse events such as myocardial infarction, arrhythmia, hypotension, bronchoconstriction and cerebrovascular events.\u003c\/p\u003e\nWARNINGS \u0026amp; PRECAUTIONS\n\u003cp\u003eIn studying patients in whom cardiac disease is known or suspected, care should be taken to assure continuous monitoring and treatment in accordance with safe, accepted clinical procedure.\u003c\/p\u003e\n\u003cp\u003eCaution should be exercised and emergency equipment should be available when administering Cardiolite\u003csup\u003e®\u003c\/sup\u003e.\u003c\/p\u003e\n\u003cp\u003eBefore administering Cardiolite\u003csup\u003e®\u003c\/sup\u003e patients should be asked about the possibility of allergic reactions to either Cardiolite\u003csup\u003e®\u003c\/sup\u003e or Miraluma\u003csup\u003e®\u003c\/sup\u003e. Miraluma\u003csup\u003e®\u003c\/sup\u003e is an identical compound used in breast imaging.\u003c\/p\u003e\n\u003cp\u003eThe contents of the vial are intended only for use in the preparation of Technetium Tc99m Sestamibi and are not to be administered directly to the patient without first undergoing the preparative procedure.\u003c\/p\u003e\n\u003cp\u003ePlease see full prescribing information.\u003c\/p\u003e\nPRESCRIBING INFORMATION\n\u003cp\u003eCardiolite Prescribing Information\u003c\/p\u003e","brand":"Lantheus","offers":[{"title":"Default Title","offer_id":41455261188,"sku":"Cardiolite","price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/products\/Cardiolite_Single_Vial3.png?v=1574905977"},{"product_id":"ire-galli-eo-68ge-68ga-gallium-generator","title":"IRE Galli Eo 68Ge\/68Ga Gallium Generator","description":"\u003cspan\u003eToday many tracers for diagnostic imaging PET (positron emission tomography) use the fluor-18, a radioisotope with short half-life, produced in a cyclotron near the medical examinations, which requires a long and heavy material and financial investment. Gallium-68 is another radioisotope equally favourable for PET imaging with physical characteristics similar to fluor-18, its half-life is also very short but it has the advantage of being obtained more easily and at lower cost through a generator germanium-68 \/ gallium-68 used directly in the radiopharmacy.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eTo facilitate the preparation of radiopharmaceuticals using gallium-68 without compromising the safety of operators and patients, the Galli Eo™ generator produced by IRE ELiT is a fully integrated, closed system to get rapidly highly concentrated and very pure preparations minimizing loss of activity. The design quite innovative limits the risk of error and contamination. Finally, this generator can be used manually or connected to a synthesis module. This optimal system for using labelling kit with gallium-68 will probably enable, thanks to imaging, a better management of cancer (neuroendocrine cancers, prostate cancer...) and other infectious diseases.\u003c\/span\u003e","brand":"IRE","offers":[{"title":"20mCi","offer_id":89537249284,"sku":"IRE Ga68 20mCi","price":0.0,"currency_code":"AUD","in_stock":true},{"title":"30mCi","offer_id":89537282052,"sku":"IRE Ga68 30mCi","price":0.0,"currency_code":"AUD","in_stock":true},{"title":"40mCi","offer_id":89537314820,"sku":"IRE Ga68 40mCi","price":0.0,"currency_code":"AUD","in_stock":true},{"title":"50mCi","offer_id":89537347588,"sku":"IRE Ga68 50mCi","price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/products\/Galli_Eo3.png?v=1509226838"},{"product_id":"pyp-radpharm","title":"PYP Radpharm","description":"\u003ch5\u003eDESCRIPTION\u003c\/h5\u003e\n\u003cp\u003eThis Kit consists of sterile, pyrogen free lyophilised ingredients which need reconstitution with sodium chloride injection. Reconstituted PYP Radpharm is a diagnostic pharmaceutical administered by intravenous injection and is suitable for blood pool imaging.\u003c\/p\u003e\n\u003ch5\u003eCONTENTS \u0026amp; PRESENTATION\u003c\/h5\u003e\n\u003cp\u003ePYP Radpharm is supplied as a carton of 5 sterile, pyrogen free, vacuum sealed multidose 8 mL vials. Each vial contains 30 mg sodium pyrophosphate and 9 mg stannous chloride anhydrous (5.6 mg stannous ion) as a lyophilised powder. The product contains no preservatives.\u003c\/p\u003e\n\u003ch5\u003eCONTRAINDICATIONS\u003c\/h5\u003e\n\u003cp\u003eTechnetium-99m with a physical half life of 6 hours decays by isomeric transition to technetium-99. Photons associated with this transition that are useful for detection and imaging studies are in Table 1. \u003cbr\u003e\u003cbr\u003eTable 1. \u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003ePrincipal Radiation Emission Data Principal Radiation Mean Percent per Disintegration Mean Energy (keV) Gamma-2 89.1 140.5 Reference: D A Weber et al. \"MIRD: Radionuclide Data and Decay Schemes\", The Society of Nuclear Medicine Inc. New York, 1989. Table 2. Physical Decay Chart for Technetium-99m Hours Fraction Remaining Hours Fraction Remaining 0 1.000 7 0.446 1 0.891 8 0.397 2 0.794 9 0.354 3 0.707 10 0.315 4 0.630 11 0.281 5 0.561 12 0.250 6 0.500\u003c\/p\u003e\n\u003ch5\u003eSAFETY INFORMATION\u003c\/h5\u003e\n\u003cp\u003eCardiolite\u003csup\u003e®\u003c\/sup\u003e has been rarely associated with acute severe allergic and anaphylactic events of angioedema and generalized urticaria.  In some patients the allergic symptoms developed on the second injection during Cardiolite\u003csup\u003e®\u003c\/sup\u003eimaging.  The most frequently reported adverse events include headache, chest pain\/angina, ST segment changes on ECG, nausea, and abnormal taste and smell.\u003c\/p\u003e\n\u003cp\u003eInfrequently, death has occurred 4 to 24 hours after Tc99m Sestamibi use and is usually associated with exercise stress testing (See Section 5.2). Pharmacologic induction of cardiovascular stress may be associated with serious adverse events such as myocardial infarction, arrhythmia, hypotension, bronchoconstriction and cerebrovascular events.\u003c\/p\u003e\n\u003ch5\u003eWARNINGS \u0026amp; PRECAUTIONS\u003c\/h5\u003e\n\u003cp\u003eIn studying patients in whom cardiac disease is known or suspected, care should be taken to assure continuous monitoring and treatment in accordance with safe, accepted clinical procedure.\u003c\/p\u003e\n\u003cp\u003eCaution should be exercised and emergency equipment should be available when administering Cardiolite\u003csup\u003e®\u003c\/sup\u003e.\u003c\/p\u003e\n\u003cp\u003eBefore administering Cardiolite\u003csup\u003e®\u003c\/sup\u003e patients should be asked about the possibility of allergic reactions to either Cardiolite\u003csup\u003e®\u003c\/sup\u003e or Miraluma\u003csup\u003e®\u003c\/sup\u003e. Miraluma\u003csup\u003e®\u003c\/sup\u003e is an identical compound used in breast imaging.\u003c\/p\u003e\n\u003cp\u003eThe contents of the vial are intended only for use in the preparation of Technetium Tc99m Sestamibi and are not to be administered directly to the patient without first undergoing the preparative procedure.\u003c\/p\u003e\n\u003cp\u003ePlease see full prescribing information.\u003c\/p\u003e\n\u003ch5\u003ePRESCRIBING INFORMATION\u003c\/h5\u003e\n\u003cp\u003eCardiolite Prescribing Information\u003c\/p\u003e","brand":"Radpharm","offers":[{"title":"Default Title","offer_id":5704225718303,"sku":"PYP 1986\/1","price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/products\/PYP.jpg?v=1574910802"},{"product_id":"mdp-radpharm","title":"MDP Radpharm","description":"\u003cp\u003e\u003cspan\u003eRadpharm MDP is supplied as sterile, pyrogen free, lyophilised powder, under nitrogen \u003c\/span\u003e\u003cspan\u003ein borosilicate Type 1 glass 10mL vial for intravenous injection following reconstitution \u003c\/span\u003e\u003cspan\u003ewith non-pyrogenic 99mTc as pertechnetate sodium (99mTcO4-).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT INFORMATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Radpharm HDP Product Information\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/files\/RADPHARM_HDP_PI.pdf?v=1639030185\"\u003e\u003cimg height=\"37\" width=\"136\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/files\/pdf_download.png?v=1486377456\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003eDESCRIPTION\u003c\/h5\u003e\n\u003cp\u003eRadpharm MDP is supplied as sterile, pyrogen free, lyophilised powder, under nitrogen in borosilicate Type 1 glass 10mL vial for intravenous injection following reconstitution with non-pyrogenic 99mTc as pertechnetate sodium (99mTcO4-)\u003cbr\u003e\u003cbr\u003eThe reconstituted product is a clear, colourless liquid.\u003c\/p\u003e\n\u003cp\u003eEach 10mL tinted vial contains: Sodium oxidronate 3.15mg as an active ingredient; Stannous chloride dihydrate 0.297mg, Gentisic acid 0.84mg and Sodium chloride 29mg as excipients.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eRadpharm MDP contains no antimicrobial preservatives.\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003e\u003cbr\u003e\u003c\/h5\u003e\n\u003ch5\u003eINDICATIONS\u003c\/h5\u003e\n\u003cp\u003eTechnetium [99mTc] Sodium Oxidronate may be used as a skeletal imaging agent to delineate areas of altered osteogenesis in adult patients.\u003c\/p\u003e\n\u003ch5\u003e\u003cbr\u003e\u003c\/h5\u003e\n\u003ch5\u003eSAFETY INFORMATION\u003c\/h5\u003e\n\u003cp\u003eThis class of compounds is known to complex cations such as calcium. Particular caution should be used with patients who have, or who may be predisposed to hypocalcemia (alkalosis).\u003cbr\u003e\u003cbr\u003eThe content of the kit are not radioactive. However, after sodium pertechnetate [99mTc] is added, adequate shielding of the final preparation must be maintained to minimize radiation exposure to occupational workers and patients.\u003cbr\u003e\u003cbr\u003eAdequate hydration of the patient is recommended before and after examination to promote urinary flow. Also, urination is recommended as often as possible for 4 to 6 hours after the examination to reduce bladder exposure radiation.\u003cbr\u003e\u003cbr\u003eFor each patient, exposure to ionising radiation must be justifiable on the basis of likely benefit. The activity administered must be such that the resulting dose is as low as reasonably achievable bearing in mind the need to obtain the intended diagnostic or therapeutic result.\u003cbr\u003e\u003cbr\u003eFor most diagnostic investigations using a nuclear medicine procedure the radiation dose delivered (EDE) is less than 20mSv. Higher doses may be justified in some clinical circumstances.\u003cbr\u003e\u003cbr\u003eRadiopharmaceuticals should only be used by physicians who are qualified by specific training in the safe use and handling of radionuclides.\u003cbr\u003e\u003cbr\u003eContents of the vial are intended only for use in the preparation of Technetium [99mTc] Sodium Oxidronate.\u003cbr\u003e\u003cbr\u003eThe radioactivity of the dose should be checked with a suitable instrument immediately prior to administration.\u003cbr\u003e\u003cbr\u003eDisposal of all radioactive wastes should be carried out in accordance with the NHMRC “Code of Practice for the Disposal of Radioactive Wastes by the User” (1985).\u003cbr\u003e\u003cbr\u003eUSE IN PATIENTS WITH IMPAIRED RENAL FUNCTION\u003cbr\u003e\u003cbr\u003ePatients with renal impairment or suffering from renal obstructions may give rise to a higher level of radiation exposure.\u003cbr\u003e\u003cbr\u003eUSE IN PATIENTS WITH IMPAIRED GASTROINTESTINAL TRACT\u003cbr\u003e\u003cbr\u003ePatients with gastrointestinal tract obstructions may give rise to a higher level of radiation exposure.\u003cbr\u003e\u003cbr\u003eWOMEN OF CHILD BEARING AGE\u003cbr\u003e\u003cbr\u003eExaminations using radiopharmaceuticals, especially those elective in nature, of women of childbearing capability, should be performed during the first 10 days following the onset of menses.\u003cbr\u003e\u003cbr\u003eUSE IN PREGNANCY\u003cbr\u003e\u003cbr\u003eWomen of reproductive age presenting for a Technetium [99mTc] Sodium Oxidronate study must be carefully interviewed to assess the likelihood of pregnancy. Irradiation of a foetus should be avoided whenever possible.\u003cbr\u003e\u003cbr\u003eTechnetium [99mTc] Sodium Oxidronate should only be given to a pregnant woman if in the judgement of the treating physician the expected benefits outweigh the potential hazards. In cases where medical radiation exposure is justified and considered necessary, the practice should be optimized in order to both minimize the dose to the foetus and achieve a diagnostic study2. It is suggested that in order to achieve this, the use of smaller administered activities and longer imaging times, together with maternal hydration and frequent voiding will lead to a reduced dose to the foetus and a clinically diagnostic study.If clinically justifiable a slight postponement of the examination to a later stage of the pregnancy will also lead to a reduced dose to the foetus2. It should be noted that contamination from radionuclide and radiopharmaceutical impurities can considerably affect the amount of activity transferred to the foetus.Therefore,in order to avoid unjustified doses to the foetus, attention should be paid to quality control of radiopharmaceutical compounds administered.\u003cbr\u003e\u003cbr\u003eUSE DURING LACTATION\u003cbr\u003e\u003cbr\u003eTechnetium [99mTc] Sodium Oxidronate is excreted in human milk. If the patient is breast-feeding following administration of Technetium [99mTc] Sodium Oxidronate a procedure should be in place to ensure that the infant will receive a total effective dose of no more than 1mSv3. In order to achieve this it is recommended that the patient express and store milk prior to administration of Technetium [99mTc] Sodium Oxidronate. Following administration of Technetium [99mTc] Sodium Oxidronate a 1 hour interruption to breast feeding and reduced contact with the infant is recommended. During this period of interruption it is recommended that the mother express and discard at least one fraction of milk. Where sample counting facilities are available it may be preferable to directly measure the concentration of the radionuclide in the breast milk to determine the time at which breastfeeding can resume.\u003cbr\u003e\u003cbr\u003eTo ensure the infant receives a total effective dose of no more than 1mSv breast feeding may resume when the milk activity concentration falls on or below 1kBq\/mL3. It should be noted that contamination from radionuclide and radiopharmaceutical impurities can considerably affect the amount of activity in the milk. Therefore, attention should be paid to quality control of radiopharmaceutical compounds administered, in order to avoid unjustified doses to the infant.\u003cbr\u003e\u003cbr\u003eCARCINOGENESIS\u003cbr\u003e\u003cbr\u003eCarcinogenesis, Mutagenesis and Impairment of Fertility\u003cbr\u003e\u003cbr\u003eNo long term animal studies have been performed to evaluate carcinogenic or mutagenic potential effects on the foetus.\u003c\/p\u003e\n\u003ch5\u003eADVERSE EFFECTS\u003c\/h5\u003e\n\u003cp\u003eAdverse reactions to Technetium [99mTc] Sodium Oxidronate are rare. However some hypersensitivity reactions, dermatological manifestations (erythema) and diaphoresis, as well as nausea, vomiting and heartburn have been infrequently associated with Technetium [99mTc] Oxidronate administration.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eHypersensitivity and allergic reactions can often be treated with a non-selective histamine H1 antagonist.\u003cbr\u003e\u003cbr\u003eBody as a Whole: hypersensitivity reactions.\u003cbr\u003eDigestive: nausea, vomiting, heartburn.\u003cbr\u003eSkin and Appendages: dermatological manifestations (erythema), injection site\u003cbr\u003einflammation\/reaction.\u003c\/p\u003e","brand":"Radpharm","offers":[{"title":"Default Title","offer_id":5711438381087,"sku":"SKEL 1986\/1","price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/products\/DMSA_24989741-79c0-460a-b46b-4b0dcf259821.jpg?v=1574910600"},{"product_id":"hdp-radpharm","title":"HDP Radpharm","description":"\u003cp\u003e\u003cspan\u003eRadpharm HDP is supplied as sterile, pyrogen free, lyophilised powder, under nitrogen \u003c\/span\u003e\u003cspan\u003ein borosilicate Type 1 glass 10mL vial for intravenous injection following reconstitution \u003c\/span\u003e\u003cspan\u003ewith non-pyrogenic 99mTc as pertechnetate sodium (99mTcO4-).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT INFORMATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/files\/RADPHARM_HDP_PI.pdf?v=1639030185\" title=\"Radpharm HDP Product Information\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/files\/pdf_download.png?v=1486377456\" alt=\"\" width=\"136\" height=\"37\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003eDESCRIPTION\u003c\/h5\u003e\n\u003cp\u003eRadpharm HDP is supplied as sterile, pyrogen free, lyophilised powder, under nitrogen in borosilicate Type 1 glass 10mL vial for intravenous injection following reconstitution with non-pyrogenic 99mTc as pertechnetate sodium (99mTcO4-)\u003cbr\u003e\u003cbr\u003eThe reconstituted product is a clear, colourless liquid.\u003c\/p\u003e\n\u003cp\u003eEach 10mL tinted vial contains: Sodium oxidronate 3.15mg as an active ingredient; Stannous chloride dihydrate 0.297mg, Gentisic acid 0.84mg and Sodium chloride 29mg as excipients.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eRadpharm HDP contains no antimicrobial preservatives.\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003ch5\u003eINDICATIONS\u003c\/h5\u003e\n\u003cp\u003eTechnetium [99mTc] Sodium Oxidronate may be used as a skeletal imaging agent to delineate areas of altered osteogenesis in adult patients.\u003c\/p\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003ch5\u003eSAFETY INFORMATION\u003c\/h5\u003e\n\u003cp\u003eThis class of compounds is known to complex cations such as calcium. Particular caution should be used with patients who have, or who may be predisposed to hypocalcemia (alkalosis).\u003cbr\u003e\u003cbr\u003eThe content of the kit are not radioactive. However, after sodium pertechnetate [99mTc] is added, adequate shielding of the final preparation must be maintained to minimize radiation exposure to occupational workers and patients.\u003cbr\u003e\u003cbr\u003eAdequate hydration of the patient is recommended before and after examination to promote urinary flow. Also, urination is recommended as often as possible for 4 to 6 hours after the examination to reduce bladder exposure radiation.\u003cbr\u003e\u003cbr\u003eFor each patient, exposure to ionising radiation must be justifiable on the basis of likely benefit. The activity administered must be such that the resulting dose is as low as reasonably achievable bearing in mind the need to obtain the intended diagnostic or therapeutic result.\u003cbr\u003e\u003cbr\u003eFor most diagnostic investigations using a nuclear medicine procedure the radiation dose delivered (EDE) is less than 20mSv. Higher doses may be justified in some clinical circumstances.\u003cbr\u003e\u003cbr\u003eRadiopharmaceuticals should only be used by physicians who are qualified by specific training in the safe use and handling of radionuclides.\u003cbr\u003e\u003cbr\u003eContents of the vial are intended only for use in the preparation of Technetium [99mTc] Sodium Oxidronate.\u003cbr\u003e\u003cbr\u003eThe radioactivity of the dose should be checked with a suitable instrument immediately prior to administration.\u003cbr\u003e\u003cbr\u003eDisposal of all radioactive wastes should be carried out in accordance with the NHMRC “Code of Practice for the Disposal of Radioactive Wastes by the User” (1985).\u003cbr\u003e\u003cbr\u003eUSE IN PATIENTS WITH IMPAIRED RENAL FUNCTION\u003cbr\u003e\u003cbr\u003ePatients with renal impairment or suffering from renal obstructions may give rise to a higher level of radiation exposure.\u003cbr\u003e\u003cbr\u003eUSE IN PATIENTS WITH IMPAIRED GASTROINTESTINAL TRACT\u003cbr\u003e\u003cbr\u003ePatients with gastrointestinal tract obstructions may give rise to a higher level of radiation exposure.\u003cbr\u003e\u003cbr\u003eWOMEN OF CHILD BEARING AGE\u003cbr\u003e\u003cbr\u003eExaminations using radiopharmaceuticals, especially those elective in nature, of women of childbearing capability, should be performed during the first 10 days following the onset of menses.\u003cbr\u003e\u003cbr\u003eUSE IN PREGNANCY\u003cbr\u003e\u003cbr\u003eWomen of reproductive age presenting for a Technetium [99mTc] Sodium Oxidronate study must be carefully interviewed to assess the likelihood of pregnancy. Irradiation of a foetus should be avoided whenever possible.\u003cbr\u003e\u003cbr\u003eTechnetium [99mTc] Sodium Oxidronate should only be given to a pregnant woman if in the judgement of the treating physician the expected benefits outweigh the potential hazards. In cases where medical radiation exposure is justified and considered necessary, the practice should be optimized in order to both minimize the dose to the foetus and achieve a diagnostic study2. It is suggested that in order to achieve this, the use of smaller administered activities and longer imaging times, together with maternal hydration and frequent voiding will lead to a reduced dose to the foetus and a clinically diagnostic study.If clinically justifiable a slight postponement of the examination to a later stage of the pregnancy will also lead to a reduced dose to the foetus2. It should be noted that contamination from radionuclide and radiopharmaceutical impurities can considerably affect the amount of activity transferred to the foetus.Therefore,in order to avoid unjustified doses to the foetus, attention should be paid to quality control of radiopharmaceutical compounds administered.\u003cbr\u003e\u003cbr\u003eUSE DURING LACTATION\u003cbr\u003e\u003cbr\u003eTechnetium [99mTc] Sodium Oxidronate is excreted in human milk. If the patient is breast-feeding following administration of Technetium [99mTc] Sodium Oxidronate a procedure should be in place to ensure that the infant will receive a total effective dose of no more than 1mSv3. In order to achieve this it is recommended that the patient express and store milk prior to administration of Technetium [99mTc] Sodium Oxidronate. Following administration of Technetium [99mTc] Sodium Oxidronate a 1 hour interruption to breast feeding and reduced contact with the infant is recommended. During this period of interruption it is recommended that the mother express and discard at least one fraction of milk. Where sample counting facilities are available it may be preferable to directly measure the concentration of the radionuclide in the breast milk to determine the time at which breastfeeding can resume. \u003cbr\u003e\u003cbr\u003eTo ensure the infant receives a total effective dose of no more than 1mSv breast feeding may resume when the milk activity concentration falls on or below 1kBq\/mL3. It should be noted that contamination from radionuclide and radiopharmaceutical impurities can considerably affect the amount of activity in the milk. Therefore, attention should be paid to quality control of radiopharmaceutical compounds administered, in order to avoid unjustified doses to the infant.\u003cbr\u003e\u003cbr\u003eCARCINOGENESIS \u003cbr\u003e\u003cbr\u003eCarcinogenesis, Mutagenesis and Impairment of Fertility\u003cbr\u003e\u003cbr\u003eNo long term animal studies have been performed to evaluate carcinogenic or mutagenic potential effects on the foetus.\u003c\/p\u003e\n\u003ch5\u003eADVERSE EFFECTS\u003c\/h5\u003e\n\u003cp\u003eAdverse reactions to Technetium [99mTc] Sodium Oxidronate are rare. However some hypersensitivity reactions, dermatological manifestations (erythema) and diaphoresis, as well as nausea, vomiting and heartburn have been infrequently associated with Technetium [99mTc] Oxidronate administration.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eHypersensitivity and allergic reactions can often be treated with a non-selective histamine H1 antagonist.\u003cbr\u003e\u003cbr\u003eBody as a Whole: hypersensitivity reactions.\u003cbr\u003eDigestive: nausea, vomiting, heartburn.\u003cbr\u003eSkin and Appendages: dermatological manifestations (erythema), injection site\u003cbr\u003einflammation\/reaction.\u003c\/p\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Radpharm","offers":[{"title":"Default Title","offer_id":5711469215775,"sku":"HDP 2015\/1","price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/products\/HDP.jpg?v=1574909601"},{"product_id":"dtpa-radpharm","title":"DTPA Radpharm","description":"\u003cp\u003e\u003cspan\u003eRadpharm DTPA consists or sterile. pyrogen free,Jtapnmsed ingredients which need reconstitution with SOdium Pertecnnetate t\"Tc) lfltCClion to produce a tectinetlum [IIIITl-rc) pentetate complex suital\u0026gt;te for renal imaging. \u003cbr data-mce-fragment=\"1\"\u003eThe precise structure of the technetium (\"-le) pentetate compleK Is not known at tnls time. \u003cbr data-mce-fragment=\"1\"\u003eTechnetium j-.,.c] pentetate Is a diagnostic pharmaceutical administered by intravenous Injection. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT INFORMATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/files\/RADPHARM_HDP_PI.pdf?v=1639030185\" title=\"Radpharm HDP Product Information\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/files\/pdf_download.png?v=1486377456\" alt=\"\" width=\"136\" height=\"37\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003eDESCRIPTION\u003c\/h5\u003e\n\u003cp\u003eDTPA Radpharm Is supplied as a carton of 5 sterile, pyrogen free. vacuum \u003cbr\u003esealed Multi-dose 8 ml vials. \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eEach vial contains 5 mg pentetic acid and 1 mg stannous chloride anhydrous as a lyophilised powder. \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe product contains no preservatives.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eINDICATIONS\u003c\/h5\u003e\n\u003cp\u003eTechnetium 99mTc Pentetate may be used as a renal perfusion imaging pharmaceutical. \u003c\/p\u003e\n\u003ch5\u003eSAFETY INFORMATION\u003c\/h5\u003e\n\u003cp\u003eGENERAL\u003cbr\u003eRadiopharmaceuticals should be used only by physicians who are qualified by specific training in the safe use and handling of radionuclides. \u003cbr\u003eContents of the vial\/s are intended only for use in the preparation of 99mTc pentetate.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eThe radioactivity of the dose should be checked with a suitable instrument immediately prior to administration. \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eDisposal of all radioactive wastes snouI0 be carried out in accordance with the NH \u0026amp; MRC \"Code of Practice for me Disposal or Radioactive Wastes \u003cbr\u003eby tile user\"' (1985).\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eUSE IN PREGNANCY\u003cbr\u003eTecnnetium-99m radiopharmaceuticals should only be given to a pregnant woman If in the judgement of the treating physician the expected benefits outweigh the potential hazards\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eUSE DURING LACTATION\u003cbr\u003eTecnnellum-99m is excreted in human milk. Interruption to breast feeding Is necessary after the administration of 99mTc pentetate for a period less than 12hr.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e(Reference: L.K. Harding, A. Bossuyt, s. Pellet, C. Remers, J.N. TaI001, \u003cbr\u003e\"Recommendations for nuclear medicine physicians regarding breastfeeding mothers\", Eur.J.NUCI.Med., 1995, 22, BP17).\u003c\/p\u003e\n\u003ch5\u003eADVERSE EFFECTS\u003c\/h5\u003e\n\u003cp\u003eFor each patient, exposure to ionising radiation must be justifiable on the basis or likely benefit. The activity administered must be such that the resulting dose is as low as reasonably achievable bearing in mind the need to obtain the intended diagnostic or therapeutic result.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eExposure to ionising radlation Is linked with cancer induction and a potential for development of hereditary defects. For diagnostic nuclear medicine investigations the current evidence suggests that these adverse effects will occur with low frequency because or the low radiation doses incurred. \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eFor most diagnostic inves119ations using a nuclear medicine procedure the radiation dose delivered (EDE) Is less than 20 msv. Higher doses may be justified in some clinical circumstances.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eIn Isolated cases the following adverse reactions have been reported: flushing, dizziness. dyspnoea. itch, urticaria and hypotension.\u003c\/p\u003e\n\u003ch5\u003eARTG\u003c\/h5\u003e\n\u003cp\u003eARTG entry for Medicine Registered\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eARTG No:\u003c\/strong\u003e 14327\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSponsor:\u003c\/strong\u003e Global Medical Solutions Australia Pty Limited T\/A Radpharm Scientific\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePostal Address:\u003c\/strong\u003e PO Box 3334 BMDC, BELCONNEN, ACT, 2617 Australia\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eARTG Start Date:\u003c\/strong\u003e 5\/09\/1991\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Category:\u003c\/strong\u003e Medicine\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStatus:\u003c\/strong\u003e Active\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApproval Area:\u003c\/strong\u003e Drug Safety Evaluation Branch\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eARTG Summary:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Radpharm HDP Product Information\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/files\/RADPHARM_HDP_PI.pdf?v=1639030185\"\u003e\u003cimg height=\"37\" width=\"136\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/files\/pdf_download.png?v=1486377456\" data-mce-selected=\"1\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Radpharm","offers":[{"title":"Default Title","offer_id":5711473344543,"sku":"DTPA 1990\/1","price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/products\/DTPA.jpg?v=1574910075"},{"product_id":"dmsa-radpharm","title":"DMSA Radpharm","description":"\u003cp\u003eRadpharm DMSA consists of sterile, pyrogen free lyophilised ingredients which need reconstitution with sodium pertechnetate[99mTc] injection to produce a technetium[99mTc] succimer complex suitable for renal imaging.\u003cbr\u003eThe precise structure of the technetium[99mTc] succimer complex is\u003cbr\u003enot known at this time.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eTechnetium[99mTc] succimer is a diagnostic pharmaceutical administered\u003cbr\u003eby intravenous injection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePRODUCT INFORMATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Radpharm DMSA Product Information\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/files\/Radpharm_DMSA_PI.pdf?v=1647774108\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/files\/pdf_download.png?v=1486377456\" alt=\"\" width=\"136\" height=\"37\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003eDESCRIPTION\u003c\/h5\u003e\n\u003cp\u003eRadpharm DMSA consists of sterile, pyrogen free lyophilised ingredients which need reconstitution with sodium pertechnetate[99mTc] injection to produce a technetium[99mTc] succimer complex suitable for renal imaging.\u003cbr\u003e\u003cbr\u003eThe precise structure of the technetium[99mTc] succimer complex is\u003cbr\u003enot known at this time.\u003cbr\u003e\u003cbr\u003eTechnetium[99mTc] succimer is a diagnostic pharmaceutical administered\u003cbr\u003eby intravenous injection.\u003c\/p\u003e\n\u003ch5\u003eINDICATIONS\u003c\/h5\u003e\n\u003cp\u003eThis Kit consists of sterile, pyrogen free lyophilised ingredients which need reconstitution with sodium pertechnetate[99mTc] injection to produce a technetium[99mTc] succimer complex suitable for renal imaging.\u003c\/p\u003e\n\u003ch5\u003eSAFETY INFORMATION\u003c\/h5\u003e\n\u003cp\u003eDMSA Radpharm is supplied as a carton of 5 sterile, pyrogen free, vacuum sealed multidose 8 mL vials.\u003cbr\u003e\u003cbr\u003eEach vial contains 1 mg succimer (meso-2,3-dimercaptosuccinic acid),\u003cbr\u003e0.4 mg stannous chloride anhydrous, 0.7 mg ascorbic acid and 50.0 mg\u003cbr\u003einositol as a lyophilised powder.\u003cbr\u003e\u003cbr\u003eThe product contains no preservatives.\u003c\/p\u003e\n\u003ch5\u003eARTG No\u003cbr\u003e\n\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eARTG No: \u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e324000\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Name: \u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRadioisotope calibration system for diagnostic or therapeutic radiopharmaceuticals - Radioisotope calibration system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSponsor Name:\u003c\/strong\u003e  Global Medical Solutions Australia Pty Ltd\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSponsor’s Own Reference:\u003c\/strong\u003e  GMS-Comecer-R2 Cal System\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEntry Type:\u003c\/strong\u003e  Included\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDate of Entry:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e25\/09\/2019\u003c\/p\u003e","brand":"Radpharm","offers":[{"title":"Default Title","offer_id":5711474032671,"sku":"DMS 1990\/1","price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/products\/DMSA.jpg?v=1574910388"},{"product_id":"calcium-phytate-colloid-radpharm","title":"Calcium Phytate Colloid Radpharm","description":"\u003ch5\u003eDESCRIPTION\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eKit for the Preparation of Technetium[99mTc] Calcium Phytate Colloid\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eInjection for Liver\/Spleen Imaging.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe agent comprises sterile, pyrogen free lyophilised ingredients which\u003cbr\u003eneed reconstitution with sodium pertechnetate[99mTc] injection and addition\u003cbr\u003eof Calcium Radpharm to produce a technetium[99mTc] calcium phytate colloid\u003cbr\u003esuitable for liver\/spleen imaging. The precise structure of the technetium[99mTc]\u003cbr\u003ecalcium phytate colloid is not known at this time. Technetium[99mTc] calcium phytate colloid is a diagnostic pharmaceutical administered by\u003cbr\u003eintravenous injection.\u003c\/p\u003e\n\u003ch5\u003eCONTENTS \u0026amp; PRESENTATION\u003c\/h5\u003e\n\u003cp\u003eThis is a composite kit consisting of a PHYTATE Radpharm vial (lyophilised)\u003cbr\u003eand a CALCIUM Radpharm vial (solution). PHYTATE Radpharm is supplied\u003cbr\u003eas a carton of 5 sterile, pyrogen free, vacuum sealed 10 mL vials containing\u003cbr\u003e23.4 mg phytic acid and 1.0 mg stannous chloride anhydrous as a lyophilised powder. CALCIUM Radpharm is supplied as a carton of 5 sterile, pyrogen\u003cbr\u003efree 8 mL vials containing a 1.2 mL solution of 5 mg\/mL potassium hydrogen phthalate and 13.7 mg\/mL calcium chloride in Water for Injections BP. The\u003cbr\u003eproduct contains no preservatives.\u003c\/p\u003e\n\u003ch5\u003eCONTRAINDICATIONS\u003c\/h5\u003e\n\u003cp\u003eTechnetium-99m with a physical half life of 6 hours decays by isomeric\u003cbr\u003etransition to technetium-99. Photons associated with this transition that are\u003cbr\u003euseful for detection and imaging studies are listed in Table 1.\u003cbr\u003e\u003cbr\u003eTable 1. \u003cspan\u003ePrincipal Radiation Emission Data\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.6542%; text-align: center;\"\u003ePrincipal Radiation\u003c\/td\u003e\n\u003ctd style=\"width: 33.3458%; text-align: center;\"\u003eMean % per Disintigration\u003c\/td\u003e\n\u003ctd style=\"width: 31%; text-align: center;\"\u003eMean Energy (keV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.6542%; text-align: center;\"\u003eGamma-2\u003c\/td\u003e\n\u003ctd style=\"width: 33.3458%; text-align: center;\"\u003e89.1\u003c\/td\u003e\n\u003ctd style=\"width: 31%; text-align: center;\"\u003e140.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e     \u003c\/p\u003e\n\u003cp\u003eReference: D A Weber et al. \"MIRD: Radionuclide Data and Decay Schemes\", The Society of Nuclear Medicine Inc. New York, 1989.\u003c\/p\u003e\n\u003cp\u003eTable 2. Physical Decay Chart for Technetium-99m\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 120.5px;\"\u003e\u003cspan\u003eHours\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 136px;\"\u003eFraction Remaining\u003c\/td\u003e\n\u003ctd style=\"width: 118px;\"\u003eHours\u003c\/td\u003e\n\u003ctd style=\"width: 134.5px;\"\u003eFraction Remaining\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 120.5px;\"\u003e0\u003c\/td\u003e\n\u003ctd style=\"width: 136px;\"\u003e1.000\u003c\/td\u003e\n\u003ctd style=\"width: 118px;\"\u003e7\u003c\/td\u003e\n\u003ctd style=\"width: 134.5px;\"\u003e0.446\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 120.5px;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"width: 136px;\"\u003e0.891\u003c\/td\u003e\n\u003ctd style=\"width: 118px;\"\u003e8\u003c\/td\u003e\n\u003ctd style=\"width: 134.5px;\"\u003e0.397\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 120.5px;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"width: 136px;\"\u003e0.794\u003c\/td\u003e\n\u003ctd style=\"width: 118px;\"\u003e9\u003c\/td\u003e\n\u003ctd style=\"width: 134.5px;\"\u003e0.354\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 120.5px;\"\u003e3\u003c\/td\u003e\n\u003ctd style=\"width: 136px;\"\u003e0.707\u003c\/td\u003e\n\u003ctd style=\"width: 118px;\"\u003e10\u003c\/td\u003e\n\u003ctd style=\"width: 134.5px;\"\u003e0.315\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 120.5px;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"width: 136px;\"\u003e0.630\u003c\/td\u003e\n\u003ctd style=\"width: 118px;\"\u003e11\u003c\/td\u003e\n\u003ctd style=\"width: 134.5px;\"\u003e0.281\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 120.5px;\"\u003e5\u003c\/td\u003e\n\u003ctd style=\"width: 136px;\"\u003e0.561\u003c\/td\u003e\n\u003ctd style=\"width: 118px;\"\u003e12\u003c\/td\u003e\n\u003ctd style=\"width: 134.5px;\"\u003e0.250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 120.5px;\"\u003e6\u003c\/td\u003e\n\u003ctd style=\"width: 136px;\"\u003e0.500\u003c\/td\u003e\n\u003ctd style=\"width: 118px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 134.5px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e                     \u003c\/p\u003e\n\u003ch5\u003eEXTERNALRADIATION\u003c\/h5\u003e\n\u003cp\u003eThe specific gamma ray constant for technetium-99m is 0.19 mGy\/MBq-h\u003cbr\u003eat 1 cm. The first half value thickness of lead (Pb) for technetium-99m is\u003cbr\u003e0.2 mm. Attenuation by lead is given in Table 3.\u003c\/p\u003e\n\u003cp\u003eTable 3: Radiation Attenuation by Lead Shielding\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 25.7813px;\"\u003e\n\u003ctd style=\"width: 48.028%; text-align: center; height: 25.7813px;\"\u003e Shield Thickness mm (Pb)\u003c\/td\u003e\n\u003ctd style=\"width: 46.972%; text-align: center; height: 25.7813px;\"\u003e\u003cspan\u003eCoefficient of Attenuation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"width: 48.028%; text-align: center; height: 22px;\"\u003e0.95\u003c\/td\u003e\n\u003ctd style=\"width: 46.972%; text-align: center; height: 22px;\"\u003e0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"width: 48.028%; text-align: center; height: 22px;\"\u003e1.8\u003c\/td\u003e\n\u003ctd style=\"width: 46.972%; text-align: center; height: 22px;\"\u003e0.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"width: 48.028%; text-align: center; height: 22px;\"\u003e2.7\u003c\/td\u003e\n\u003ctd style=\"width: 46.972%; text-align: center; height: 22px;\"\u003e0.001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"width: 48.028%; text-align: center; height: 22px;\"\u003e3.6\u003c\/td\u003e\n\u003ctd style=\"width: 46.972%; text-align: center; height: 22px;\"\u003e0.0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\n\u003cbr\u003ePHARMACOLOGY\u003c\/h5\u003e\n\u003cp\u003eThe liver is an organ of the reticuloendothelial system and it consists of two\u003cbr\u003emain cell types. The parenchymal (polyclonal) cells perform the metabolic functions and account for 85% of the cell population. The reticuloendothelial (Kupfer) cells, which are also present in the spleen and bone marrow, phagocytose foreign particles of colloidal dimensions. Radioactive colloids\u003cbr\u003eare rapidly removed from the circulation by these cells. Any lesion that\u003cbr\u003edisplaces normal liver tissue will appear as a photopenic site as it does not\u003cbr\u003etake up the radiocolloid.\u003c\/p\u003e\n\u003ch5\u003eINDICATIONS\u003c\/h5\u003e\n\u003cp\u003eTechnetium [99mTc] calcium phytate colloid may be used as a liver\/spleen imaging pharmaceutical for determining liver size and shape, and for investigation of a malignancy, infections, trauma and cirrhosis.\u003c\/p\u003e\n\u003ch5\u003eCONTRAINDICATIONS\u003c\/h5\u003e\n\u003cp\u003eNone known.\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003ePRECAUTIONS\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003cbr\u003eRadiopharmaceuticals should be used only by physicians who are qualified\u003cbr\u003eby specific training in the safe use and handling of radionuclides.\u003cbr\u003eContents of the vial are intended only for use in the preparation of technetium [99mTc] calcium phytate colloid. The radioactivity of the dose should be\u003cbr\u003echecked with a suitable instrument immediately prior to administration.\u003cbr\u003eDisposal of all radioactive wastes should be carried out in accordance with\u003cbr\u003ethe NH \u0026amp; MRC \"Code of Practice for the Disposal of Radioactive Wastes\u003cbr\u003eby the User\" (1985).\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eUse in Pregnancy\u003c\/strong\u003e\u003cbr\u003eTechnetium-99m radiopharmaceuticals should only be given to a pregnant woman if in the judgement of the treating physician the expected benefits outweigh the potential hazards.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eUse During Lactation\u003c\/strong\u003e\u003cbr\u003eTechnetium-99m is excreted in human milk. Interruption to breast feeding\u003cbr\u003eis not essential after the administration of technetium[99mTc] calcium\u003cbr\u003ephytate colloid (a mother can be reassured by advising an interruption\u003cbr\u003eof 4hr). (Reference: L.K. Harding, A. Bossuyt, S. Pellet, C. Reiners, J.N.\u003cbr\u003eTalbot, \"Recommendations for nuclear medicine physicians regarding breastfeeding\", Eur.J.Nucl.Med., 1995, 22, BP17).\u003c\/p\u003e\n\u003ch5\u003eADVERSE REACTIONS\u003c\/h5\u003e\n\u003cp\u003eFor each patient, exposure to ionising radiation must be justifiable on the\u003cbr\u003ebasis of likely benefit. The activity administered must be such that the\u003cbr\u003eresulting dose is as low as reasonably achievable bearing in mind the need\u003cbr\u003eto obtain the intended diagnostic or therapeutic result. Exposure to ionising\u003cbr\u003eradiation is linked with cancer induction and a potential for development\u003cbr\u003eof hereditary defects. For diagnostic nuclear medicine investigations the\u003cbr\u003ecurrent evidence suggests that these adverse effects will occur with low\u003cbr\u003efrequency because of the low radiation doses incurred. For most diagnostic investigations using a nuclear medicine procedure the radiation dose\u003cbr\u003edelivered (EDE) is less than 20 mSv. Higher doses may be justified in some\u003cbr\u003eclinical circumstances. Adverse reactions have not been reported for this\u003cbr\u003eproduct, to date.\u003c\/p\u003e\n\u003ch5\u003eDOSAGE AND ADMINISTRATION\u003c\/h5\u003e\n\u003cp\u003eRecommended intravenous dose for the normal adult is 120-160 MBq.\u003c\/p\u003e","brand":"Radpharm","offers":[{"title":"Default Title","offer_id":5711898476575,"sku":"PHY 1986\/1","price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/products\/Radpharm_-49.jpg?v=1522144315"},{"product_id":"radiacwash","title":"Radiacwash","description":"\u003cp style=\"font-weight: 400;\"\u003eRadiacwash™ has been used extensively in hospitals, universities, laboratories and reactor facilities since 1951. It is the first and most popular general purpose decontamination solution specifically created for the fast and safe removal of the entire spectrum of nuclidic radioactivity.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/files\/086-335.pdf?6933581753749051662\" title=\"Data Sheet\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/files\/pdf_download.png?v=1486377456\" alt=\"\" width=\"151\" height=\"41\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003eOVERVIEW\u003c\/h5\u003e\n\u003cp\u003eOVERVIEW\u003c\/p\u003e\n\u003cp\u003eRadiacwash™ is a concentrated solution designed to rapidly control radioactive contamination and remove radioactive particles from surfaces by a two-way action. First, it will sequester metallic ions which contaminate surfaces. Second, it lifts up and firmly suspends the contaminating particles, allowing contamination to be rinsed away with hard, soft or salt water.\u003c\/p\u003e\n\u003cp\u003eRadiacwash™ will remove general laboratory contaminants such as soil, grease, oil, blood, resides, resins, and tissue. It can be used safely on all surfaces, either straight or diluted, including skin, cloth, all metals, glass, floors, walls, leather, rubber, porcelain, plastic, laboratory instruments, utensils and equipment.\u003c\/p\u003e\n\u003cp\u003eRadiacwash™ is a synergic liquid compound that optimally combines a number of different chemical and physical principles causing it to act as a surface-wetting sequestering agent, chelater, carrier, ion-exchanger, emulsifier, solvent, complexer, peptizer and detergent.\u003c\/p\u003e\n\u003ch5\u003eFEATURES\u003c\/h5\u003e\n\u003cp\u003eFEATURES\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eRadiacwash™ has a pH of 5, less than .008% Halides, contains no phosphates, chromates, silicates, enzymes, borates, aluminates, carbonates, and inert fillers that can interfere with sensitive analytical procedures. Radiacwash™ is non-alkaline, non-corrosive, and biodegradable.\u003c\/p\u003e\n\u003ch5\u003eSPECIFICATIONS\u003c\/h5\u003e\n\u003cp\u003eSPECIFICATIONS\u003c\/p\u003e\n\u003ch5\u003eDIMENSIONS\u003c\/h5\u003e\n\u003cp\u003eDIMENSIONS\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Radiacwash","offers":[{"title":"4L Bottle","offer_id":31257871581302,"sku":"005-100","price":0.0,"currency_code":"AUD","in_stock":true},{"title":"1L Spray Mist Bottle","offer_id":31257871614070,"sku":"005-400","price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/products\/radiacwash.jpg?v=1574767991"},{"product_id":"radiacwash-towlettes","title":"Radiacwash Decontaminating Wipes","description":"\u003cp\u003eRadiacwash™ Decontaminating Wipes are the most efficient and safest way to remove radiocontamination from hands and small objects. Simply dispense the Radiacwash pre-moistened wipes from the canister, scrub hands thoroughly and wash the contamination away with running water. Each wipe measures 7\"\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ex 8\".\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/files\/086-335.pdf?6933581753749051662\" title=\"Data Sheet\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/files\/pdf_download.png?v=1486377456\" alt=\"\" width=\"151\" height=\"41\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003eOVERVIEW\u003c\/h5\u003e\n\u003cp\u003eOVERVIEW\u003c\/p\u003e\n\u003cp\u003eRadiacwash™ has been used extensively in hospitals, universities, laboratories and reactor facilities since 1951. It is the first and most popular general purpose decontamination solution specifically created for the fast and safe removal of the entire spectrum of nuclidic radioactivity.\u003c\/p\u003e\n\u003cp\u003eRadiacwash™ is a concentrated solution designed to rapidly control radioactive contamination and remove radioactive particles from surfaces by a two-way action. First, it will sequester metallic ions which contaminate surfaces. Second, it lifts up and firmly suspends the contaminating particles, allowing contamination to be rinsed away with hard, soft or salt water.\u003c\/p\u003e\n\u003cp\u003eRadiacwash™ will remove general laboratory contaminants such as soil, grease, oil, blood, resides, resins, and tissue. It can be used safely on all surfaces, either straight or diluted, including skin, cloth, all metals, glass, floors, walls, leather, rubber, porcelain, plastic, laboratory instruments, utensils and equipment.\u003c\/p\u003e\n\u003cp\u003eRadiacwash™ is a synergic liquid compound that optimally combines a number of different chemical and physical principles causing it to act as a surface-wetting sequestering agent, chelater, carrier, ion-exchanger, emulsifier, solvent, complexer, peptizer and detergent.\u003c\/p\u003e\n\u003ch5\u003eFEATURES\u003c\/h5\u003e\n\u003cp\u003eFEATURES\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cli\u003eDecontaminating wipes\u003c\/li\u003e\n\u003cli\u003ePre-moistened with Radiacwash™ solution\u003c\/li\u003e\n\u003cli\u003eIdeal for hands and small objects\u003c\/li\u003e\n\u003cli\u003e75 wipes per canister\u003c\/li\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eSPECIFICATIONS\u003c\/h5\u003e\n\u003cp\u003eSPECIFICATIONS\u003c\/p\u003e\n\u003cp\u003eRadiacwash™ has a pH of 5, less than .008% Halides, contains no phosphates, chromates, silicates, enzymes, borates, aluminates, carbonates, and inert fillers that can interfere with sensitive analytical procedures. Radiacwash™ is non-alkaline, non-corrosive, and biodegradable.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003eDIMENSIONS\u003c\/h5\u003e\n\u003cp\u003eDIMENSIONS\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Radiacwash","offers":[{"title":"Default Title","offer_id":31257911918710,"sku":"005-301","price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/products\/Radiacwash_Decon_Wipes.png?v=1574768378"},{"product_id":"radiacwash-spray-mist","title":"Radiacwash Spray Mist","description":"\u003cp style=\"font-weight: 400;\"\u003e\u003cspan\u003eRadiacwash™ Spray Mist combines the power and economy of Radiacwash™ with the convenience of aerosols. Radiacwash™ Spray Mist is a Radiacwash™ Solution packed into a special high pressure mist applicator. When the activator is depressed, over 200 lb of pressure is created at the nozzle. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cspan\u003eThe pressure misting effect allows Radiacwash™ to penetrate around and under contaminants and lift them off the surface into solution to be wiped up and disposed.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/files\/086-335.pdf?6933581753749051662\" title=\"Data Sheet\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/files\/pdf_download.png?v=1486377456\" alt=\"\" width=\"151\" height=\"41\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003eOVERVIEW\u003c\/h5\u003e\n\u003cp\u003eOVERVIEW\u003c\/p\u003e\n\u003cp\u003eRadiacwash™ has been used extensively in hospitals, universities, laboratories and reactor facilities since 1951. It is the first and most popular general purpose decontamination solution specifically created for the fast and safe removal of the entire spectrum of nuclidic radioactivity.\u003c\/p\u003e\n\u003cp\u003eRadiacwash™ is a concentrated solution designed to rapidly control radioactive contamination and remove radioactive particles from surfaces by a two-way action. First, it will sequester metallic ions which contaminate surfaces. Second, it lifts up and firmly suspends the contaminating particles, allowing contamination to be rinsed away with hard, soft or salt water.\u003c\/p\u003e\n\u003cp\u003eRadiacwash™ will remove general laboratory contaminants such as soil, grease, oil, blood, resides, resins, and tissue. It can be used safely on all surfaces, either straight or diluted, including skin, cloth, all metals, glass, floors, walls, leather, rubber, porcelain, plastic, laboratory instruments, utensils and equipment.\u003c\/p\u003e\n\u003cp\u003eRadiacwash™ is a synergic liquid compound that optimally combines a number of different chemical and physical principles causing it to act as a surface-wetting sequestering agent, chelater, carrier, ion-exchanger, emulsifier, solvent, complexer, peptizer and detergent.\u003c\/p\u003e\n\u003ch5\u003eFEATURES\u003c\/h5\u003e\n\u003cp\u003eFEATURES\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eRadiacwash™ has a pH of 5, less than .008% Halides, contains no phosphates, chromates, silicates, enzymes, borates, aluminates, carbonates, and inert fillers that can interfere with sensitive analytical procedures. Radiacwash™ is non-alkaline, non-corrosive, and biodegradable.\u003c\/p\u003e\n\u003ch5\u003eSPECIFICATIONS\u003c\/h5\u003e\n\u003cp\u003eSPECIFICATIONS\u003c\/p\u003e\n\u003ch5\u003eDIMENSIONS\u003c\/h5\u003e\n\u003cp\u003eDIMENSIONS\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Radiacwash","offers":[{"title":"Default Title","offer_id":31257986957430,"sku":"005-400","price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/products\/radiacwash-spray_2460138f-e8fb-432a-8df5-fdcc42cfeaec.jpg?v=1574768777"},{"product_id":"ivy-biomedical-metallic-ecg-leads","title":"Ivy Biomedical - Metallic ECG Leads","description":"\u003cp\u003e\u003cspan\u003eThe Model 7600 is Ivy Biomedical System’s 5th generation cardiac trigger monitor used in applications requiring precision ECG R-wave synchronization for gating host systems on and off. The Model 7600 incorporates an intuitive, menu-driven, touch-screen user interface, simplifying operation for clinicians and technicians.\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003eThe 7000 Series leads are available in multiple lengths and all come with a 12 month Warranty.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/files\/7000X-EN_3781-00-16.pdf?v=1639519395\" title=\"Ivy Biomedical Metallic ECG Leads Data Sheet\"\u003e\u003cimg height=\"41\" width=\"151\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/files\/pdf_download.png?v=1486377456\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003eOVERVIEW\u003c\/h5\u003e\n\u003cp\u003eOVERVIEW\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Model 7600 is a favorite for use in cardiovascular diagnostic imaging studies, especially in gamma camera, nuclear medicine, and molecular imaging applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAcquiring reliable and consistent ECG triggers can often be a challenging task, and selecting the right ECG vector can be problematic. The Model 7600 uses a 4-lead ECG configuration in order to provide automatic lead selection capability. This feature monitors each ECG vector simultaneously, and automatically selects the best ECG lead for triggering, thereby delivering reliable triggering even under challenging or changing patient conditions. Red markers on the ECG waveform indicate when and where triggering occurred for visual verification and assurance.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eFEATURES\u003c\/h5\u003e\n\u003cp\u003eFEATURES\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Model 7600 offers a compact 6” diagonal color TFT display, ECG simulator, heart rate limit alarms, RS-232 communication interface, multiple factory configured trigger output pulse width and amplitude options, optional integrated strip chart recorder, optional roll stand mount, and more at an affordable price.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eSPECIFICATIONS\u003c\/h5\u003e\n\u003cp\u003eSPECIFICATIONS\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Model 7600 offers trigger pulse output performance with less than 2ms of delay, and ±75µs of dither (accuracy), ensuring consistent and reliable triggering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAll Ivy Biomedical products comply with global standards for safety, EMC, quality management, and environmental requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eDIMENSIONS\u003c\/h5\u003e\n\u003cp\u003eDIMENSIONS\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eAvailable in 24\"\/30\"\/36\" lengths.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Ivy Biomedical","offers":[{"title":"24\"","offer_id":39799683317900,"sku":"590433 – 24”","price":0.0,"currency_code":"AUD","in_stock":true},{"title":"30\"","offer_id":39799683350668,"sku":"590433 – 24”-2","price":0.0,"currency_code":"AUD","in_stock":true},{"title":"36\"","offer_id":39799683383436,"sku":"590433 – 24”-3","price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/products\/7600_1.jpg?v=1639521629"},{"product_id":"vdc-606-touch-screen-dose-calibrator","title":"VDC-606 Touch Screen Dose Calibrator","description":"\u003cp\u003eThis state-of-the-art touch-screen dose calibrator combines the best of both worlds: it has the extended functionality of a software-based computer and the stability of a stand-alone unit.\u003c\/p\u003e\n\u003ch3\u003eTouch Screen Dose Calibrator | VDC-606\u003cbr\u003eProduct highlights\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e10’’ touch screen medical certified PC\u003c\/li\u003e\n\u003cli\u003eEasy to use\u003c\/li\u003e\n\u003cli\u003eIBC-LITE software included\u003c\/li\u003e\n\u003cli\u003eAccurate and fast measurements\u003c\/li\u003e\n\u003cli\u003eFDA approved and Medical Device\u003c\/li\u003e\n\u003cli\u003eAvailable for vials and syringes\u003c\/li\u003e\n\u003cli\u003eVIK-202 or VIK-203 ionisation chamber\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eVDC-606 Features\u003c\/h2\u003e\n\u003cp\u003eLike all Comecer dose calibrators, each model is used in combination with a completely digital VIK-202 or VIK-203 ionization chamber.\u003cbr\u003eThe device is specifically designed to make the user feel right at home. Every bit of functionality is through touch and optimized to support the workflow. Performing the daily quality control will only take a tap or two on the brilliant and crisp 10” screen.\u003c\/p\u003e\n\u003cp\u003eBuilt-in functionality includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMo-99 breakthrough test\u003c\/li\u003e\n\u003cli\u003eIdentity test\u003c\/li\u003e\n\u003cli\u003eDaily\/weekly\/yearly tests\u003c\/li\u003e\n\u003cli\u003eContainers\/geometries\u003c\/li\u003e\n\u003cli\u003eSyringe preparation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eVDC-606 has CE marking for medical devices and is FDA approved.\u003c\/p\u003e\n\u003cp\u003eThe heart of every Comecer dose calibrator is the ionization chamber: a completely digital detector that gives a fast and reliable reading.\u003cbr\u003eThe 100% digital output allows the detector to be flexibly integrated into other instruments or structures with no need for a converter or a separate reading unit.\u003cbr\u003e\u003cspan class=\"HwtZe\" lang=\"en\"\u003e\u003cspan class=\"jCAhz ChMk0b\"\u003e\u003cspan class=\"ryNqvb\"\u003eThe VIK-202 ionization chamber has a measuring range up to 2 Ci of F-18;\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"jCAhz ChMk0b\"\u003e\u003cspan class=\"ryNqvb\"\u003ethe VIK-203 ionization chamber is also available which has a measuring range up to 20 Ci of F-18.\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"jCAhz ChMk0b\"\u003e\u003cspan class=\"ryNqvb\"\u003eSince Comecer produces its own ionization chambers in-house, we can meet specific requirements with special dimensions or measures\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e. As Comecer produces its own ionisation chambers in-house, we can meet specific requirements with special dimensions or measurements.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eStandard accessories\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIonization chamber (VIK-202 or VIK-203)\u003c\/li\u003e\n\u003cli\u003ePower supply\u003c\/li\u003e\n\u003cli\u003eIBC-LITE software\u003c\/li\u003e\n\u003cli\u003eWell liner\u003c\/li\u003e\n\u003cli\u003eSample holder.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOptional accessories\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eExtra lead shielding (20\/50 mm Pb)\u003c\/li\u003e\n\u003cli\u003eMo-99 breakthrough set\u003c\/li\u003e\n\u003cli\u003eCopper dipper\u003c\/li\u003e\n\u003cli\u003eExtra well liner\u003c\/li\u003e\n\u003cli\u003eExtra dipper\u003c\/li\u003e\n\u003cli\u003eLabel printer\u003c\/li\u003e\n\u003cli\u003eCheck sources.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Comecer","offers":[{"title":"Default Title","offer_id":46213660999820,"sku":null,"price":10000.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/files\/VDC-606-Touch-Screen-Dose-Calibrator-780x751.png?v=1770251617"},{"product_id":"ibc-dose-calibrator-1","title":"IBC Dose Calibrator","description":"\u003cp\u003e\u003cspan\u003eThe IBC DOSE CALIBRATOR is a completely digital dose calibrator with a reading software. The ionisation chamber can be connected directly to a PC with Windows. Both the reading system and the control system are managed by the IBC-LITE reading software.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eIBC Dose Calibrator | Comecer\u003cbr\u003eProduct highlights\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eQuality control tests for the ionisation chamber\u003c\/li\u003e\n\u003cli\u003eSimultaneous control of two ionization chambers\u003c\/li\u003e\n\u003cli\u003eInterface with IBC management software\u003c\/li\u003e\n\u003cli\u003eFDA approved and Medical Device\u003c\/li\u003e\n\u003cli\u003eRadionuclide purity test of the radiopharmaceutical\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eVIK-202 or VIK-203 ionisation chamber\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eIBC Features\u003c\/h2\u003e\n\u003cp\u003eLike all Comecer dose calibrators, each model is used in combination with a completely digital VIK-202 or VIK-203 ionization chamber.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe IBC-LITE software offers an easy, intuitive touch screen interface that supports all the functions needed for dose calibration in a Microbiological Safety Cabinet and in preparing single-patient doses. The IBC Dose Calibrator is extremely suitable for Radiopharmacy use within a Nuclear Medicine department, as it can be easily integrated into any type of Microbiological Safety Cabinet.\u003c\/p\u003e\n\u003cp\u003eThe IBC-DOSE CALIBRATOR supports all printers that use Windows drivers. The labels can be defined by the user via a dedicated tool in IBC-Lite that is complete and easy to use.\u003c\/p\u003e\n\u003cp\u003eThe IBC DOSE CALIBRATOR has CE Medical Device marking and is FDA approved.\u003c\/p\u003e\n\u003ch2\u003eStandard supply\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIBC-LITE Software (PC non included)\u003c\/li\u003e\n\u003cli\u003eIonisation chamber (VIK-202 or VIK-203)\u003c\/li\u003e\n\u003cli\u003ePower supply for Ionisation chamber\u003c\/li\u003e\n\u003cli\u003eWell liner\u003c\/li\u003e\n\u003cli\u003eSample holder\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOptional accessories\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eExtra lead shielding (20\/50 mm Pb)\u003c\/li\u003e\n\u003cli\u003eMo-99 breakthrough set\u003c\/li\u003e\n\u003cli\u003eCopper dipper\u003c\/li\u003e\n\u003cli\u003eExtra well liner\u003c\/li\u003e\n\u003cli\u003eExtra dipper\u003c\/li\u003e\n\u003cli\u003eLabel printer\u003c\/li\u003e\n\u003cli\u003eFanless miniPC\u003c\/li\u003e\n\u003cli\u003eDipper lift\u003c\/li\u003e\n\u003cli\u003eCheck sources\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFeatures IBC-LITE software\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGAMP-5 validated\u003c\/li\u003e\n\u003cli\u003eBuilt-in isotope list\u003c\/li\u003e\n\u003cli\u003eIsotope preset list\u003c\/li\u003e\n\u003cli\u003eSuitable for measuring vials and syringes\u003c\/li\u003e\n\u003cli\u003eUser-definable containers\u003c\/li\u003e\n\u003cli\u003eFuture dose calculation\u003c\/li\u003e\n\u003cli\u003eQuality control tests for the Ionisation chamber:\n\u003cul\u003e\n\u003cli\u003eStability, linearity and null effect\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eMolybdenum breakthrough test\u003c\/li\u003e\n\u003cli\u003eBackground subtraction\u003c\/li\u003e\n\u003cli\u003ePrinting user-definable labels\u003c\/li\u003e\n\u003cli\u003eTouch screen control\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eMinimum system specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePC system with Windows XP or higher\u003c\/li\u003e\n\u003cli\u003e1x RS-232 interface for the Ionisation chamber\u003c\/li\u003e\n\u003cli\u003e1x USB interface for the optionally label printer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eUpdate to IBC-Nuclear Medicine and IBC-GMP Radiopharmacy\u003c\/h2\u003e\n\u003cp\u003eIBC-LITE can be updated to the software versions to manage activity in Nuclear Medicine and Radiopharmacy:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIBC-Nuclear Medicine and IBC-GMP Radiopharmacy\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.comecer.com\/nuclear-medicine\/radiochemistry-pet-cyclotron-conventional-nuclear-medicine\/radioactivity-measurement-systems\/ibc-nuclear-medicine-management-sysstem\/\" title=\"IBC Nuclear Medicine – Management System\"\u003eIBC-Nuclear Medicine\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eis a client-server based software environment to manage the daily routines in a Nuclear Medicine department. The software guarantees full traceability from ordering stock to injection of the patient dose. The software also offers the functionality to implement user definable protocols for a guided and controlled workflow to standardise the preparation process from stock to patient dose.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.comecer.com\/nuclear-medicine\/radiochemistry-pet-cyclotron-conventional-nuclear-medicine\/radioactivity-measurement-systems\/ibc-pro-hotlab-management-system\/\" title=\"IBC-GMP Radiopharmacy Management System\"\u003eIBC-GMP Radiopharmacy\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eis a state-of-the-art solution based on client\/server to manage the daily routine in radiopharmaceutical production centres that require “GMP” traceability. In these centres, the IBC-GMP Radiopharmacy management system offers a high level of integrated automation to standardise processes. In Radiopharmacies, the software supports order management, preparation and dispatch of ready-made multi-dose vials and\/or syringes. The software guarantees full traceability from ordering stock to the end product.\u003c\/p\u003e\n\u003cp\u003eToday’s GMP guidelines dictate that all processes need to be reported, validated and justified. Thanks to IBC-GMP Radiopharmacy, the highest level of GMP compliance can be integrated.\u003c\/p\u003e","brand":"Comecer","offers":[{"title":"Default Title","offer_id":46258640486540,"sku":null,"price":10000.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/files\/IBC-Dose-Calibrator-780x751.png?v=1770599087"},{"product_id":"doseit-patient-dose-preparation-software","title":"DoseIT Patient dose preparation software","description":"\u003cp\u003eComecer DoseIT is an easy-to-use dose preparation application build on top of the DoseApp of the SmartLab platform.\u003c\/p\u003e\n\u003cp\u003eIt will give you an easy solution “From planning to injection” to prepare the requested patient dose with the integrated DICOM patient list directly at hand!\u003c\/p\u003e\n\u003ch2\u003eAutomate patient records, streamline your workflow!\u003c\/h2\u003e\n\u003ch2\u003eDoseIT - Comecer patient dose preparation software\u003c\/h2\u003e\n\u003ch2\u003eFeatures:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBi-Directional DICOM connection\u003c\/li\u003e\n\u003cli\u003eMo99 Breakthrough test directly on the dose calibrator\u003c\/li\u003e\n\u003cli\u003eEasy sorting and searching in patient planning\u003c\/li\u003e\n\u003cli\u003eEasy inventory management per radiopharmaceutical\u003c\/li\u003e\n\u003cli\u003eAll advantages of the DoseApp functionality for the dose calibrator\u003c\/li\u003e\n\u003cli\u003eComplete Audit trail\u003c\/li\u003e\n\u003cli\u003eEasy configuration, Plug\u0026amp;Play\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eDoseIT Features\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDoseIT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis our new, fast and user-friendly patient dose preparation software. With its DICOM connection to the hospital information system and direct connection to the included Radionuclide Dose Calibrator and DoseApp, it provides a complete and fast solution from planning to Injection.\u003c\/p\u003e\n\u003cp\u003eThe Dose Calibrator is a complete digital Radionuclide dose calibrator.\u003c\/p\u003e\n\u003cp\u003eTogether with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDoseApp\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDoseIT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eit supports all functions required for dose calibration when preparing radiopharmaceutical doses for your patient planning.\u003c\/p\u003e\n\u003cp\u003eIn the DoseApp you can perform all the dose calibrator quality controls.\u003c\/p\u003e\n\u003cp\u003eEasy entry of the used radiopharmaceutical makes sure you have the traceability needed by regulatory from vial to patient injection.\u003c\/p\u003e\n\u003ch3\u003eSupported Quality Controls\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eZero Adjustment\u003c\/li\u003e\n\u003cli\u003eBias Correction\u003c\/li\u003e\n\u003cli\u003eBackground Adjustment\u003c\/li\u003e\n\u003cli\u003eAccuracy \u0026amp; Constancy tests\u003c\/li\u003e\n\u003cli\u003eCalibration \u0026amp; Linearity tests\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"features\"\u003eReady to transform your operations?\u003c\/h2\u003e\n\u003cp\u003eContact our sales team\u003cspan\u003e \u003c\/span\u003etoday for a free consultation and personalized guidance. We’ll determine the best solution for your department and provide a comprehensive software demo. Receive a detailed quotation tailored to your needs and get assistance with installation and validation, ensuring a smooth transition.\u003c\/p\u003e\n\u003cp\u003eWe understand that you may have some concerns, and we’re here to address them.\u003c\/p\u003e\n\u003ch3\u003eCost\u003c\/h3\u003e\n\u003cp\u003eRest assured that our system offers long-term cost savings, improved efficiency, and reduced errors, providing a positive return on investment.\u003c\/p\u003e\n\u003ch3\u003eComplexity\u003c\/h3\u003e\n\u003cp\u003eOur user-friendly software ensures a seamless transition, backed by comprehensive support, training, and onboarding services.\u003c\/p\u003e\n\u003ch3\u003eCompliance\u003c\/h3\u003e\n\u003cp\u003eOur system is fully compliant with regulatory standards, streamlining compliance processes and mitigating risks.\u003c\/p\u003e\n\u003ch3\u003eCustomization\u003c\/h3\u003e\n\u003cp\u003eWe offer a flexible solution that can be customized to align with your specific needs and workflows.\u003c\/p\u003e","brand":"Comecer","offers":[{"title":"Default Title","offer_id":46258735284364,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/files\/DoseIT_Patient-dose-preparation-software-780x743.png?v=1770600617"},{"product_id":"speedy-glove-automatic-portable-glove-integrity-tester","title":"Speedy Glove Automatic portable glove integrity tester","description":"\u003cp\u003e\u003cspan\u003eSpeedy Glove is a battery-powered glove tester that performs leak testing on gloves installed on isolators or RABS where a strict separation between the isolated area and the external environment is required. The system performs pressure decay integrity tests that comply with the requirements of \u003c\/span\u003e\u003cem\u003e\u003cstrong\u003eISO 14644-7 Annex E.5\u003c\/strong\u003e\u003c\/em\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSpeedy Glove - Automatic Glove Tester\u003c\/h2\u003e\n\u003ch2\u003eMain Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCompact size\u003c\/li\u003e\n\u003cli\u003eExtremely fast operation\u003c\/li\u003e\n\u003cli\u003eHighest accuracy\u003c\/li\u003e\n\u003cli\u003eComplete touch-screen\u003c\/li\u003e\n\u003cli\u003eRFID technology\u003c\/li\u003e\n\u003cli\u003eWi-Fi ready\u003c\/li\u003e\n\u003cli\u003eVPHP compatibility for Reverse Test\u003c\/li\u003e\n\u003cli\u003ecGMP compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eSpeedy Glove Features\u003c\/h2\u003e\n\u003cp\u003eSpeedy Glove is suitable for all isolators equipped with glove flange such as those dedicated to aseptic processes, containment processes, the manipulation of API and HAPI and the manipulation of radiopharmaceuticals. Speedy Glove is compatible with all currently available glove flanges on the market.\u003c\/p\u003e\n\u003cp\u003eThe system boasts a number of peculiar and patented characteristics which make the Speedy Glove unique on the market in terms of performance and flexibility. There is, in fact, a unique system of rapid inflation of the glove that fills it with air in a few seconds during the leak test, saving between 3 and 5 minutes each test (approximately 30% of the total time) compared to the times usually required by similar devices on the market. It does not need to be connected to pneumatic circuits or compressed air tanks but can independently manage all the phases of the glove integrity testing process.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eVPHP compatible\u003c\/h2\u003e\n\u003cp\u003eThe system is also compatible with vaporised hydrogen peroxide, hence meaning it can be completely decontaminated. This important feature, together with the extremely compact dimensions, means it can be introduced through a pre-chamber into the isolator on the gloves to be tested. Once inside it is possible, with appropriate flanges arranged as in the Comecer isolators, to activate a glove testing process that inflates the glove from the inside outwards.\u003c\/p\u003e\n\u003cdiv id=\"gallery-1\" class=\"gallery galleryid-31424 gallery-columns-2 gallery-size-large\"\u003e\n\u003cdl class=\"gallery-item\"\u003e\n\u003cdt class=\"gallery-icon landscape\"\u003e\u003ca href=\"https:\/\/www.comecer.com\/wp-content\/uploads\/2017\/11\/Speedy-Glove_outside-780x585.png\" class=\"fancybox image\" rel=\"gallery-0\" aria-controls=\"fancybox-wrap\" aria-haspopup=\"dialog\"\u003e\u003cimg decoding=\"async\" width=\"780\" height=\"585\" src=\"https:\/\/www.comecer.com\/wp-content\/uploads\/2017\/11\/Speedy-Glove_outside-780x585.png\" class=\"attachment-large size-large\" alt=\"Speedy-Glove_outside\" aria-describedby=\"gallery-1-31440\"\u003e\u003c\/a\u003e\u003c\/dt\u003e\n\u003cdd class=\"wp-caption-text gallery-caption\" id=\"gallery-1-31440\"\u003eOutside to inside testing, Speedy Glove used in the cleanroom\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cdl class=\"gallery-item\"\u003e\n\u003cdt class=\"gallery-icon landscape\"\u003e\u003ca href=\"https:\/\/www.comecer.com\/wp-content\/uploads\/2017\/11\/Speedy-Glove_inside-780x585.png\" class=\"fancybox image\" rel=\"gallery-0\" aria-controls=\"fancybox-wrap\" aria-haspopup=\"dialog\"\u003e\u003cimg decoding=\"async\" width=\"780\" height=\"585\" src=\"https:\/\/www.comecer.com\/wp-content\/uploads\/2017\/11\/Speedy-Glove_inside-780x585.png\" class=\"attachment-large size-large\" alt=\"Speedy-Glove_inside\" aria-describedby=\"gallery-1-31439\"\u003e\u003c\/a\u003e\u003c\/dt\u003e\n\u003cdd class=\"wp-caption-text gallery-caption\" id=\"gallery-1-31439\"\u003eInside to outside test, Speedy Glove used inside the isolator\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cp\u003eIn the case, in fact, of critical processes to avoid breaking the class of isolator during the test it is possible to perform this test in reverse conditions compared to the classical approach, that is by inflating the glove inwards. To avoid fluctuations of pressures that could return false negatives or false positives, the isolator in fact in traditional tests of gloves is deactivated by turning off the ventilation and by normalising the pressure towards the environment. The Speedy Glove system offers the possibility of avoiding this temporary block of the isolator operation both through any test from the inside and through the real-time monitoring of the isolator pressure (if connected with Comecer machines) able to compensate for the effect of statistical fluctuation of the internal pressure thus avoiding false alarms.\u003c\/p\u003e\n\u003ch2\u003e12 Frequently Asked Speedy Glove Questions and their Answers\u003c\/h2\u003e\n\u003cp\u003eAs we travel to industry events worldwide and present our Speedy Glove product, there are a few questions from booth visitors that generally come up. Here are the most common ones, with their answers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1. Why is it important to test glove integrity in a RABs or Isolator?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIsolator integrity is a must to guarantee an aseptic working chamber. Tightness can be verified with a test on the entire isolator, but the leak test on the full chamber volume is not sensitive enough to find a microscopic leak in one of the gloves. That is why it is fundamental to perform a specific integrity test to verify each individual glove. This is done with a device specifically designed for this delicate task, like Speedy Glove.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. When should one test glove integrity?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAs specifically stated in the EU GMP Annex 1 revision, a glove integrity test is fundamental for the correct pre- and post-production qualification in an isolator. Since the glove is one of the main sources of risk in the process, it must be precisely controlled before and after each critical phase of the production process, compatibly with its Quality Risk management and therefore with the need to guarantee the quality of the medicinal product.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. What norms and regulations apply to glove integrity testing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAt the regulatory level, the glove integrity test is described in ISO 14644-7 Annex E.5 where the use of the pressure decay test is identified as suitable for verifying any punctures or tears capable of determining a sealing problem on the isolator. However, this standard does not identify a precise set of parameters, given that times and pressure setpoints remain dependent on the type of equipment, the type of glove and the type of leak to be detected. Therefore since the standard identifies a generic method, it is necessary to support the measuring instrument with a suitable procedure development process and Performance Qualification.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. How long does it take to recharge the Speedy Glove battery?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt takes 4 hours to recharge the battery. Batteries support approximately 20-30 consequential integrity tests.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5. Why and how is RFID used by Speedy Glove?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSpeedy Glove can load the correct receipt using RFID. Each Speedy Glove is equipped with 20 RFID tags, and these are recognized up to a maximum distance of 20cm. RFID allows glove test tracing during analysis and therefore exclude operator human error.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e6. Does Speedy Glove have internal memory?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSpeedy Glove can archive around one thousand reports.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e7. Does Speedy Glove support VHP?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, Speedy Glove is compatible with VHP and can be introduced in the aseptic area.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e8. How can test result reports be saved?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eReports are saved as CSV or PDF files using the USB port or a WiFi connection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e9. Is Speedy Glove CFR Part 11 compliant?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the Speedy Glove software is CRF Part 11 compliant. Additionally, you can add IOQ protocol execution that can verify and attest compliance with CFR part 11. The device is provided with access control and internal Audit Trail, which can be visualized and exported.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e10. How can Speedy Glove adapt to different glove flanges?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSpeedy Glove is easily adaptable to glove flanges of different dimensions thanks to an interchangeable standard device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e11. How is the recipe value identified for a test?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe recipe values are identified with Performance Qualification (PQ). PQ is able to verify, using a statistical analysis with a calibrated leak, the optimal parameters to be sure to avoid false-positive and false-negative results\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e12. How can you handle different Speedy Glove units inside a single production site?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDifferent units in a single production site can be managed with the Speedy Glove Manager software, which allows centralized reporting and simultaneous management of the recipes for different units.\u003c\/p\u003e","brand":"Comecer","offers":[{"title":"Default Title","offer_id":46258742952076,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/files\/SPEEDY-GLOVE-780x555.png?v=1770600969"},{"product_id":"ibc-clinic-nuclear-medicine-management-software","title":"IBC Clinic Nuclear Medicine Management Software","description":"\u003cp\u003e\u003cspan\u003eIBC CLINIC is a complete client server solution for nuclear medicine departments that don’t need to control the process of radiopharmaceutical production. IBC CLINIC software supports an operator with patient and dose management, stock and waste, and order of ready to use radiopharmaceutical, following the regulatory guidelines.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eIBC Clinic - Nuclear Medicine Management Software\u003c\/h2\u003e\n\u003cp\u003eThe IBC CLINIC management software is a state-of-the-art client-server software system for nuclear medicine departments and imaging centers. It dynamically supports you in meeting the local regulations that you face during your daily work related to waste management, order management of ready-made radiopharmaceuticals, stock management, patient examination planning and syringe administration registration.\u003c\/p\u003e\n\u003cp\u003eWhen using multi dose vials, the software supports the preparation of syringes, based on the examination planning and with the support of the connected dose calibrator and software-based read-out. When administrating syringes to patients, the software provides the possibility to measure the syringe just before administration and directly after administration to the patient. The remainder is automatically added to your waste and the exactly administered dose can be returned to the RIS\/PACS system if a connection is available.\u003c\/p\u003e\n\u003cp\u003eThe software supports the use of a barcode scanner which reduces data entry errors. For dose measuring, the software has a fully integrated link with your dose calibrator – manual entry of the measured dose is not needed. The software supports quality controls for the connected dose calibrators (like daily check and linearity tests).\u003cbr\u003eWith IBC CLINIC it is possible to import the patient examination planning directly from the RIS\/PACS system.\u003cbr\u003eWhen you have the IRIS injector, an electronic (wireless) link is available between the IBC CLINIC software and the IRIS with respect to the examination planning, patient details and planned doses to inject.\u003c\/p\u003e\n\u003cp\u003eThe IBC CLINIC software is designed to be used in the nuclear medicine department or imaging center that does not manufacture radiopharmaceuticals, but orders ready-made bulk (multi doses), syringes or other radiopharmaceuticals at a central pharmacy or cyclotron facility. The department injects patients with a radiopharmaceutical for examination (PET\/CT scan, Gamma spectroscopy, et cetera) or administers other radiopharmaceuticals for different kinds of examinations.\u003c\/p\u003e","brand":"Comecer","offers":[{"title":"Default Title","offer_id":46258751045772,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/files\/Logo_IBC-CLINIC_2021-11_R1_piatto_COMPLETO-1-780x751.png?v=1770601167"},{"product_id":"ibc-nm-nuclear-medicine-management-software","title":"IBC NM Nuclear Medicine Management Software","description":"\u003cp\u003e\u003cspan\u003eThe IBC NM software is a complete client\/server system for nuclear medicine departments. IBC software guarantees full traceability from ordering stock to radiopharmaceutical preparation and injection of a single dose to the patient. Due to its flexible approach, the software can be configured such that your workflow can be standardized and optimized. IBC NM software supports your daily activities in the nuclear medicine department while following the regulatory guidelines.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eIBC Nuclear Medicine Management Software\u003c\/h2\u003e\n\u003cp\u003eIBC NM software supports your daily activities in the nuclear medicine department with respect to patient examination planning, radiopharmaceutical and syringe preparation, stock and waste management, dose measurement and injection to the patient, while following the guidelines of regulatory.\u003c\/p\u003e\n\u003cp\u003eIBC Nuclear Medicine is a state-of-the-art client-server management system for the nuclear medicine departments of hospitals and clinics. IBC NM adopts a flexible approach, allowing you to configure standard workflows dynamically and according to GMP regulation. Due to its flexible approach, the software can be configured such that your workflow can be standardized and according to GMP regulation.\u003c\/p\u003e\n\u003cp\u003eThe IBC Nuclear Medicine software supports your daily activities in the nuclear medicine department with respect to patient examination planning, radiopharmaceutical and syringe preparation, stock and waste management, dose measurement and injection to the patient.\u003c\/p\u003e\n\u003cp\u003eWhen administering syringes to patients, the software provides the possibility to measure the syringe just before administration and directly after administration to the patient. The remainder is automatically added to your waste and the exactly administered dose can be returned to the RIS\/PACS system if a connection is available.\u003c\/p\u003e\n\u003cp\u003eThe software supports the use of a barcode scanner which reduces data entry errors. For dose measuring, the software has a fully integrated link with your dose calibrator – manual entry of the measured dose is not needed. The software supports quality controls for the connected dose calibrators (like daily check and linearity tests).\u003c\/p\u003e\n\u003cp\u003eWith IBC Nuclear Medicine, it is possible to import the patient examination planning directly from the RIS\/PACS system via DICOM Worklist or HL7.\u003cbr\u003eWhen you have the IRIS injector, an electronic (wireless) link is available between the IBC Nuclear Medicine software and the IRIS with respect to the examination planning, patient details and planned doses to inject.\u003c\/p\u003e","brand":"Comecer","offers":[{"title":"Default Title","offer_id":46258755141772,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/files\/Logo_IBC-NM_2021-09_R1_piatto_COMPLETO-780x751.png?v=1770601304"},{"product_id":"ibc-rp-radiopharmacy-management-software","title":"IBC RP Radiopharmacy Management Software","description":"\u003cp\u003e\u003cspan\u003eIBC RP is a software for radiopharmacies and PET centers that allows the user to follow the entire production, storage, and waste management workflow in addition to managing orders and shipping. If there is a nuclear medicine department, IBC RP also allows the use of the IBC Patient Extension option, with which the user can perform the patient injections process while following regulatory guidelines.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eRadiopharmacy Management Software model IBC RP - Comecer\u003c\/h2\u003e\n\u003cp\u003eIBC RP is a software for radio pharmacy and Pet centers that allowing the user to follow the entire production, storage, and waste management workflow in addition to managing orders and shipping. If there is a nuclear medicine department, IBC RP also allows use of the IBC Patient Extension option with which the user will be able to also do the patient injections process while following regulatory.\u003c\/p\u003e\n\u003cp\u003eThe IBC Radiopharmacy software is a state-of-the-art client-server based software system for a cyclotron facility, central pharmacy and academic hospital.\u003c\/p\u003e\n\u003cp\u003eIt dynamically supports you in meeting the GMP regulations that you face during your daily routine related to inventory management, material handling, preparation, batch production, quality control and delivery of PET tracers and other radiopharmaceuticals. Due to the high level of integrated automation to standardize the processes in one software system, you finally can get rid of all the different electronic tools required to record and link all data required to meet the GMP compliance.\u003c\/p\u003e\n\u003cp\u003eIBC Radiopharmacy provides a single point of data entry, resulting in complete traceability from raw materials to release and delivery of manufactured multi or unit dose radiopharmaceuticals, reduction of data entry overhead and related errors, improved product quality and patient safety.\u003c\/p\u003e\n\u003cp\u003eA fully digital ionisation chamber can be directly connected to a standard Windows PC system. Both system read-out and system control are managed by the IBC Radiopharmacy software. Furthermore the software can be interfaced with most dose calibrators from other vendors.\u003c\/p\u003e\n\u003cp\u003eIf the facility also supports an (internal) nuclear medicine department, the IBC Radiopharmacy software can be extended with patient-related modules like injected dose registration and an HL7 or DICOM MWL link with a RIS\/PACS system in order to share the patient examination planning of the facility.\u003c\/p\u003e","brand":"Comecer","offers":[{"title":"Default Title","offer_id":46258758156428,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/files\/Logo_IBC-RP_2021-09_R1_piatto_COMPLETO-780x751.png?v=1770601404"},{"product_id":"smartguard-environmental-radiation-monitoring-system","title":"SMARTGUARD Environmental Radiation Monitoring System","description":"\u003cdiv class=\"singolo_prodotto_riassunto p-b-50\"\u003e\n\u003cp\u003eThe Comecer SmartGuard system allows any Nuclear Medicine Department, PET-Cyclotron and pharmacy to implement a controlled monitoring environment, including comprehensive means to handle and document (exceeded) alarm levels and logging of measuring data.\u003c\/p\u003e\n\u003ch2\u003eSmartGuard Environmental Radiation Monitoring System\u003c\/h2\u003e\n\u003ch2\u003eHighlights\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModular and flexible system\u003c\/li\u003e\n\u003cli\u003eReal-time monitoring\u003c\/li\u003e\n\u003cli\u003eExport event history\u003c\/li\u003e\n\u003cli\u003eVirtual maps\u003c\/li\u003e\n\u003cli\u003eEvent notification via mail\u003c\/li\u003e\n\u003cli\u003eUnlimited Detection Units\u003c\/li\u003e\n\u003cli\u003ecGMP compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eSMARTGUARD Features\u003c\/h2\u003e\n\u003ch2 id=\"features\"\u003eEnvironmental Radiation Monitoring System\u003c\/h2\u003e\n\u003cp\u003eThe system is flexible in the sense that it can be configured to meet the specific needs of a site, where these needs can be of a regulatory, production monitoring and\/or safety related nature.\u003c\/p\u003e\n\u003cp\u003eThe system is modular in the sense that there is a choice of (measurement) devices available, which can be used to build a small-scale decentralized monitoring system up to a completely centralized, department wide, monitoring system. It is always possible to add devices when required.\u003c\/p\u003e\n\u003cp\u003eSpecial attention has been paid to GMP requirements with respect to cleanable surfaces and out-of-sight cabling.\u003c\/p\u003e\n\u003ch2\u003eSystem architecture\u003c\/h2\u003e\n\u003cp\u003e\u003cimg decoding=\"async\" class=\"aligncenter size-full wp-image-26996\" src=\"https:\/\/www.comecer.com\/wp-content\/uploads\/2014\/06\/smartguard_architeture.jpg\" alt=\"SMARTGUARD Architeture\" width=\"1000\" height=\"563\"\u003e\u003c\/p\u003e\n\u003cp\u003eAt the heart of the SmartGuard system there is SmartGuard Software that allows its user to have an overview of all events in the facility, collect and analyse the data of measurements and configure and manage devices in custom designed maps of the facility.\u003c\/p\u003e\n\u003cp\u003e\u003cimg decoding=\"async\" class=\"aligncenter wp-image-76427 size-large\" src=\"https:\/\/www.comecer.com\/wp-content\/uploads\/2013\/06\/SmartGuard-Software-780x438.png\" alt=\"SmartGuard Software\" width=\"780\" height=\"438\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWhen levels are exceeded, the user will receive notifications of the event. A notification will be present when certain levels in measurements are exceeded on what place the event takes place. This way the user can take the right measurer in time when that is needed.\u003c\/li\u003e\n\u003cli\u003eCustom virtual maps that are designed to fit your facility. Every map exists out of four levels: area’s, zone’s, rooms, and devices. An Area is a part of the monitored floor in the facility, each area exists out of several rooms, with zones in them with the different devices.\u003c\/li\u003e\n\u003cli\u003eCollected data is gathered and easily read in a manner. In the software the data will be automatically collected and put into easy-to-read graphs or grids.\u003c\/li\u003e\n\u003cli\u003eEvery device that is connected to the system can be configured remotely via the software.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA web-based solution that stores, reports and exports data of monitored areas, rooms, and devices. VMS will be installed on the local server of the customer, from that point the system can be accessed using a normal browser via any computer that is connected to the server.\u003c\/p\u003e\n\u003cp\u003e\u003cimg loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-large wp-image-76441\" src=\"https:\/\/www.comecer.com\/wp-content\/uploads\/2013\/06\/SMART-GUARD_web-based_2022-04-1-780x400.png\" alt=\"SMARTGUARD - web based system\" width=\"780\" height=\"400\"\u003e\u003c\/p\u003e\n\u003cp\u003eA Detection Unit consists of a radiation detector and a controller\/display unit. The detector type varies with the task at hand.\u003c\/p\u003e\n\u003cp\u003eDetection Units for the following tasks are available:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProduction monitoring (hot cell)\u003c\/li\u003e\n\u003cli\u003eArea monitoring (rooms)\u003c\/li\u003e\n\u003cli\u003eAir monitoring (stack\/hot cell\/cyclotron)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNeutron monitoring\u003c\/strong\u003e (vault)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-84397 size-large\" src=\"https:\/\/www.comecer.com\/wp-content\/uploads\/2013\/06\/smartguard_neutron_monitor-1-780x439.jpg\" alt=\"Neutron monitoring system\" width=\"780\" height=\"439\"\u003e\u003c\/p\u003e\n\u003cp\u003eAll the Detection Units can be handled by the Controller Station. As SmartGuard is a web-based system, remote display’s (VMS-RD) can be set up in any room of the facility (for example, Radiochemistry Lab, Quality Control, etc…), to visualise the system status.\u003c\/p\u003e\n\u003cp\u003eProduction monitoring in the hot cell and area monitoring in the lab is covered by the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVRM-303 radiation monitor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efitted with a VRM-GP Geiger-Müller detector. Measuring data is available locally as well as at the central Control Station.\u003c\/p\u003e\n\u003cp\u003eFor air monitoring two Detection Units are available.\u003c\/p\u003e\n\u003cp\u003e\u003cimg loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-76448 size-large\" src=\"https:\/\/www.comecer.com\/wp-content\/uploads\/2013\/06\/smartguard-vrm-303-1-780x439.jpg\" alt=\"smartguard-vrm-303\" width=\"780\" height=\"439\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe first system (VRM-SM) is meant for measuring activity (concentration) in stacks and ventilation ducts.\u003c\/p\u003e\n\u003cp\u003eThe second system \u003cstrong\u003e(VRM-AM) is meant to measure the activity (concentration) inside of hot cells or rooms\u003c\/strong\u003e. Air from inside of the hot cells (or rooms) is sampled, standard VRM-AM supports up to four rooms. An option is available to increase this with five rooms to a total of nine rooms.\u003c\/p\u003e\n\u003cp\u003e\u003cimg loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-84404 size-large\" src=\"https:\/\/www.comecer.com\/wp-content\/uploads\/2013\/06\/smartguard_air-monitor-1-780x439.jpg\" alt=\"Air monitoring system\" width=\"780\" height=\"439\"\u003e\u003c\/p\u003e\n\u003cp\u003eIn all facilities subject to GMP regulations, installation is very important. The presence of visible cables, holes where dust can deposit, irregular surfaces, can impede good cleaning procedures.\u003c\/p\u003e\n\u003cp\u003eThanks to the use of:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHidden cables (also in case of remote detectors)\u003c\/li\u003e\n\u003cli\u003eLow profile connectors in the back panel of read-out units\u003c\/li\u003e\n\u003cli\u003eIntegrated detector\u003c\/li\u003e\n\u003cli\u003eRoughed-in cables for the installation\u003c\/li\u003e\n\u003cli\u003eit is now possible to install detectors (wall mounted) without visible cables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlso \u003cstrong\u003eremote displays (VMS-RD)\u003c\/strong\u003e are installed without visible cables and can be easily cleaned.\u003c\/p\u003e\n\u003cp\u003e\u003cimg loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-84418 size-large\" src=\"https:\/\/www.comecer.com\/wp-content\/uploads\/2013\/06\/smartguard_remote-pc-1-780x439.jpg\" alt=\"Remote control PC\" width=\"780\" height=\"439\"\u003e\u003c\/p\u003e\n\u003ch2\u003eSupply conditions\u003c\/h2\u003e\n\u003cp\u003eSome units will be powered locally. Customer must assure the line power and ground level consistency throughout the site. Most units are powered by Power over Ethernet, and we suggest that the customer is responsible for the implementation of this LAN infrastructure according to the layout supplied by Comecer.\u003c\/p\u003e\n\u003cp\u003eOf course Comecer can be of service in this process, if required.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"ecommerce\" class=\"riga-inside-prodotto p-bt-50\"\u003e\u003c\/div\u003e","brand":"Comecer","offers":[{"title":"Default Title","offer_id":46258771755148,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/files\/SmartGuard_Environmental-Monitoring-System-780x751.png?v=1770601500"},{"product_id":"iris-automated-radiopharmaceutical-multidose-injector","title":"IRIS Automated Radiopharmaceutical Multidose Injector","description":"\u003cp\u003eIRIS is a radiopharmaceutical injector that performs calibrated injections to patients, starting from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ea multi-dose solution\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof FDG or other radiopharmaceuticals.\u003c\/p\u003e\n\u003cp\u003eThe IRIS radiopharmaceutical injector is compact and easy to handle thanks to its innovative design and autonomous battery power.\u003c\/p\u003e\n\u003ch2\u003eIRIS Radiopharmaceutical Multidose Injector | Comecer\u003c\/h2\u003e\n\u003ch2\u003eProduct Highlights\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCompact design\u003c\/li\u003e\n\u003cli\u003eExtremely easy to use thanks to the ergonomic positioning of the components\u003c\/li\u003e\n\u003cli\u003eSingle, convenient control station\u003c\/li\u003e\n\u003cli\u003eAdjustable control panel\u003c\/li\u003e\n\u003cli\u003ePossibility to measure mother vial activity\u003c\/li\u003e\n\u003cli\u003ePossibility to dilute mother vial\u003c\/li\u003e\n\u003cli\u003eCompatible with multiple types of vial containers\u003c\/li\u003e\n\u003cli\u003eSupports multiple isotopes with dose calibrator\u003c\/li\u003e\n\u003cli\u003eHigh precision calculation of the dose\u003c\/li\u003e\n\u003cli\u003eCleaning procedure for disposables and mother vial\u003c\/li\u003e\n\u003cli\u003eIBC software connection link\u003c\/li\u003e\n\u003cli\u003eQuick and automatic preparation and injection of the doses to the patient\u003c\/li\u003e\n\u003cli\u003ePatient selection with automatic dose calculation\u003c\/li\u003e\n\u003cli\u003eLabel printer for infusion registration\u003c\/li\u003e\n\u003cli\u003eDICOM protocol for RIS\/PACS direct connection and work list exchange\u003c\/li\u003e\n\u003cli\u003eWireless connection to the hospital intranet\u003c\/li\u003e\n\u003cli\u003eOperating autonomy guaranteed for 8 hours.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eIRIS Features\u003c\/h2\u003e\n\u003ch2 id=\"features\"\u003eFlexibility\u003c\/h2\u003e\n\u003cp\u003eThe radioactive product is administered by a sterile\/disposable kit; after each injection to the patient, only the end part of the kit must be replaced.\u003cbr\u003eThe activity of the entire radiopharmaceutical is measured by an ionization chamber integrated into the fractioning system.\u003cbr\u003eThe multi-dose mother vial is directly loaded into the machine with its own shipping container. IRIS is designed for use with most commercially available containers. The maximum activity of the multi-dose mother vial is 30 GBq (F18 or equivalent).\u003c\/p\u003e\n\u003ch2\u003eIntegration\u003c\/h2\u003e\n\u003cp\u003eIRIS can be connected via Wi-Fi to the Hospital network to acquire patient data. After each injection, a report on the individual infusions can be printed.\u003c\/p\u003e\n\u003ch2\u003eErgonomics\u003c\/h2\u003e\n\u003cp\u003eModern technology has made it possible to achieve a very easy-to-handle machine, suited to all movement needs within hospital departments and wards.\u003cbr\u003eThe core of IRIS has a solid steel frame and is equipped with a servomotor that assists the operator in handling the device.\u003cbr\u003eThe device’s control system keeps track of the complete status of the device, battery level, movement brake, treatment, measurements, sensors and actuators.\u003cbr\u003eWhen the battery runs low, the system informs the operator promptly. When the battery is fully charged, the system is able to operate for a full working day without the need for recharge.\u003cbr\u003eIRIS’s various outer housing parts are of extremely durable and easy to clean polypropylene.\u003cbr\u003eIts sturdy construction means the device is not damaged during movements.\u003c\/p\u003e\n\u003ch2\u003eColourful thinking\u003c\/h2\u003e\n\u003cp\u003eComecer attributes great importance to design intended as research of ergonomic functionality, organised ease of use, and lightness of movement.\u003cbr\u003eAdded to this is chromatic research, which, in hospitals, contributes to making the operator’s job more serene and pleasant, also and especially in the doctor-patient relationship.\u003cbr\u003eThe wide range of subtle outer colours, together with its understated design fulfils this aim, by making IRIS even more attractive.\u003cbr\u003eThe coloured section of the outer housing can be changed and replaced with the utmost ease to suit the operative environment.\u003c\/p\u003e","brand":"Comecer","offers":[{"title":"Default Title","offer_id":46258822283404,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/files\/comecer-iris-slide.png?v=1613150002"},{"product_id":"unit-dose","title":"Unit Dose","description":"\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003e\u003cimg\u003e\u003c\/span\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003eThe right dose, at the right place, at the right time. No waste.\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003eConvenient. Efficient. Quality-assured.\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003eGMS Australia extemporaneously compounds SPECT \u0026amp; PET Radiopharmaceuticals made to order by customers for particular persons.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003eUnit dose is a complete solution to your radiopharmaceutical needs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003eIndividual doses are prepared, quality-assured and packaged for each scan.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003eDoses are delivered on time to departments for administration to patients.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003eThe unit dose service includes the retrieval, decay and disposal of all radioactive waste from delivered doses.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003eUnit dose also includes free use of GMS's Secure Insert system; a safe reliable method for handling and disposal of radioactive sharps.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003eSave time and money.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003eCONVENIENCE\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003eImproved workflow with ready- to-inject doses delivered daily.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003eReduced need for in-house compounding of doses that require multiple steps, such as heating.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003eNo need to complete additional QC on compounded ready-to-inject radiopharmaceuticals.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003eSingle point of contact for all of your department's radiopharmacy needs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003eImproved utiliisation of staff\/resources due to decreased time required for complex compounding.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003eGMS resources available to assist with troubleshooting and quality control enquiries.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003eReliable supply of compounded radiopharmaceuticals, cold reagent kits \u0026amp; raw materials allows more departments to offer a full suite of NM \u0026amp; related studies.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003eImproved access to a greater range of studies via novel \u0026amp; exclusively licensed tracers - supported by a national radiopharmacy network.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003eQUALITY\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003eNational network of TGA\/GMP licensed \u0026amp; regulated radiopharmacies supported by a comprehensive regulatory \u0026amp; quality assurance team.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003eStringent, validated quality control procedures in alignment with registered PI recommendations reduces need for in-house QC.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003eMitigate quality-related risks using TGA\/GMP-licensed and pharmacy-regulated centralised radiopharmacies.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003eBatch tracked, traceability on all released products.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003eAll activity is measured using equipment regularly calibrated to manufacturer's recommendations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003ePatient's can be assured of the quality of the radiopharmaceuticals being injected.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003eARTG-registered products used in the production of compounded radiopharmaceuticals.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003ePatient safety is protected by strict, validated SOPs and industry leading quality assurance measures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003eEFFICIENCY\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003eReduced laboratory workload and associated reduction in staff radiation exposure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003eSupply of ready-to-inject radiopharmaceuticals means staff can focus on other departmental tasks.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003eReduction in time spent by staff navigating regulatory issues.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003eUnit dose decreases the need to use an entire cold kit vial for in-house compounding for a single patient.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003eRadioactive waste can be handled more effectively and efficiently.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003eStreamlined access to Section 19, SA, orphan, unregulated \u0026amp; other low-demand products.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003eDepartment efficiency \u0026amp; patient throughput can be improved by utilising centralised radiopharmacies.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003eThe cost of therapeutic \u0026amp; international isotope orders may be significantly reduced when ordering through CRP's due to efficiencies of scale and consolidated ordering processes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003eFor Terms \u0026amp; Conditions of Unit Dose availability, please visit our Regulatory and Compliance section.\u003c\/span\u003e\u003cb\u003e\u003cspan style=\"font-family: 'Verdana',sans-serif;\"\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"GMS Australia Pty Ltd","offers":[{"title":"Default Title","offer_id":51250805309580,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/files\/Picture1.png?v=1783300818"},{"product_id":"bulk-dose","title":"Bulk Dose","description":"\u003cp\u003eBulk Dose can be a great solution for days that are unpredictable.\u003c\/p\u003e\n\u003cp\u003eBulk dose means your radioisotopes are prepared, quality-assured and packaged for your flexible daily needs.\u003c\/p\u003e\n\u003cp\u003eGMS-Australia can also provide cold kits for your department to compound and dispense.\u003c\/p\u003e\n\u003cp\u003eThe right solution\u003cspan\u003e for your department could also mean a mix of Bulk Dose and Unit Dose.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBulk Dose for flexibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUnit Dose for cost-effectiveness and quality control. \u003c\/span\u003e\u003c\/p\u003e","brand":"GMS Australia Pty Ltd","offers":[{"title":"Default Title","offer_id":51250852200588,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/files\/GMP_logo.png?v=1782769337"},{"product_id":"complete-rp-solution","title":"Complete RP Solutions","description":"\u003ch1 class=\"page-title\"\u003eUnit Dose   +   Bulk Dose   +   Cold Kits\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cimg height=\"125\" width=\"125\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/files\/Radiopharmacy_compact.png?v=1523175450\"\u003e                         \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/files\/Vial_Icon_5573f2c8-0ef3-4057-9e9a-896ea26307b9_large.png?v=1523175786\" width=\"94\" height=\"145\"\u003e                                   \u003cimg height=\"155\" width=\"95\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/files\/Cold_Kit_Icon_171b71ef-ffa3-4424-8892-13dba18df99c_large.png?v=1523175915\"\u003e\n\u003c\/div\u003e\n\u003ch2\u003eThe right solution\u003cspan\u003e for your department could be Unit Dose for cost-effectiveness and Bulk Dose for flexibility.\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eBulk Dose for unpredictable, easy-to-prepare doses.\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cspan\u003eUnit Dose for expensive or high quality-assurance doses.\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cspan\u003eCold Kits for cost-effective stock control.\u003c\/span\u003e\u003c\/h3\u003e","brand":"GMS Australia Pty Ltd","offers":[{"title":"Default Title","offer_id":51250852462732,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/files\/Screenshot2026-07-06114223.png?v=1783302166"},{"product_id":"iodine-131","title":"Iodine 131","description":"\u003cp\u003e\u003cb\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003eIodine- 131 is available in capsule and solution\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 11.0pt;\"\u003eRadioactive iodine, specifically iodine-131 (I-131), can be administered in capsule or liquid form and is absorbed by the thyroid gland, where it emits radiation that destroys overactive thyroid cells or cancerous tissues.\u003c\/span\u003e\u003c\/p\u003e","brand":"NTP","offers":[{"title":"Default Title","offer_id":51251231883404,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/files\/Screenshot2026-07-06124029.png?v=1783305665"},{"product_id":"fluorine-18","title":"Fluorine 18","description":"\u003cp\u003eFluorine-18 can be labelled using either direct or indirect methods. \u003cbr\u003e\u003cbr\u003eLabelled peptides enable non-invasive visualisation and quantification of biological processes at the molecular level, aiding in drug development and therapeutic monitoring. \u003cbr\u003e\u003cbr\u003eFluorine-18 has a relatively long half-life (110 minutes) compared to other isotopes, allowing for centralised production and easier imaging procedures. \u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"GMS Australia Pty Ltd","offers":[{"title":"Default Title","offer_id":51251316490380,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/files\/Liquidsolution_1.png?v=1783308898"},{"product_id":"lutetium-177","title":"Lutetium 177","description":"\u003ch1\u003eLutetium-177 (Lu-177) is primarily used in targeted radionuclide therapy for treating neuroendocrine tumours and metastatic prostate cancer, offering effective treatment with minimal damage to healthy tissues.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/h1\u003e","brand":"GMS Australia Pty Ltd","offers":[{"title":"Default Title","offer_id":51251365249164,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/files\/Liquid_solution_2.png?v=1783309428"}],"url":"https:\/\/www.globalmedicalsolutions.com.au\/collections\/radiopharmacy.oembed?page=2","provider":"GMS Australia Pty Ltd","version":"1.0","type":"link"}