{"product_id":"ibc-dose-calibrator","title":"IBC Dose Calibrator","description":"\u003cp\u003e\u003cspan\u003eThe IBC DOSE CALIBRATOR is a completely digital dose calibrator with a reading software. The ionisation chamber can be connected directly to a PC with Windows. Both the reading system and the control system are managed by the IBC-LITE reading software.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eIBC Dose Calibrator | Comecer\u003cbr\u003eProduct highlights\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eQuality control tests for the ionisation chamber\u003c\/li\u003e\n\u003cli\u003eSimultaneous control of two ionization chambers\u003c\/li\u003e\n\u003cli\u003eInterface with IBC management software\u003c\/li\u003e\n\u003cli\u003eFDA approved and Medical Device\u003c\/li\u003e\n\u003cli\u003eRadionuclide purity test of the radiopharmaceutical\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eVIK-202 or VIK-203 ionisation chamber\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"section-title\"\u003eIBC Features\u003c\/h3\u003e\n\u003cp\u003eLike all Comecer dose calibrators, each model is used in combination with a completely digital VIK-202 or VIK-203 ionization chamber.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe IBC-LITE software offers an easy, intuitive touch screen interface that supports all the functions needed for dose calibration in a Microbiological Safety Cabinet and in preparing single-patient doses. The IBC Dose Calibrator is extremely suitable for Radiopharmacy use within a Nuclear Medicine department, as it can be easily integrated into any type of Microbiological Safety Cabinet.\u003c\/p\u003e\n\u003cp\u003eThe IBC-DOSE CALIBRATOR supports all printers that use Windows drivers. The labels can be defined by the user via a dedicated tool in IBC-Lite that is complete and easy to use.\u003c\/p\u003e\n\u003cp\u003eThe IBC DOSE CALIBRATOR has CE Medical Device marking and is FDA approved.\u003c\/p\u003e\n\u003ch3\u003eStandard supply\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIBC-LITE Software (PC non included)\u003c\/li\u003e\n\u003cli\u003eIonisation chamber (VIK-202 or VIK-203)\u003c\/li\u003e\n\u003cli\u003ePower supply for Ionisation chamber\u003c\/li\u003e\n\u003cli\u003eWell liner\u003c\/li\u003e\n\u003cli\u003eSample holder\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOptional accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExtra lead shielding (20\/50 mm Pb)\u003c\/li\u003e\n\u003cli\u003eMo-99 breakthrough set\u003c\/li\u003e\n\u003cli\u003eCopper dipper\u003c\/li\u003e\n\u003cli\u003eExtra well liner\u003c\/li\u003e\n\u003cli\u003eExtra dipper\u003c\/li\u003e\n\u003cli\u003eLabel printer\u003c\/li\u003e\n\u003cli\u003eFanless miniPC\u003c\/li\u003e\n\u003cli\u003eDipper lift\u003c\/li\u003e\n\u003cli\u003eCheck sources\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFeatures IBC-LITE software\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGAMP-5 validated\u003c\/li\u003e\n\u003cli\u003eBuilt-in isotope list\u003c\/li\u003e\n\u003cli\u003eIsotope preset list\u003c\/li\u003e\n\u003cli\u003eSuitable for measuring vials and syringes\u003c\/li\u003e\n\u003cli\u003eUser-definable containers\u003c\/li\u003e\n\u003cli\u003eFuture dose calculation\u003c\/li\u003e\n\u003cli\u003eQuality control tests for the Ionisation chamber:\n\u003cul\u003e\n\u003cli\u003eStability, linearity and null effect\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eMolybdenum breakthrough test\u003c\/li\u003e\n\u003cli\u003eBackground subtraction\u003c\/li\u003e\n\u003cli\u003ePrinting user-definable labels\u003c\/li\u003e\n\u003cli\u003eTouch screen control\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMinimum system specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePC system with Windows XP or higher\u003c\/li\u003e\n\u003cli\u003e1x RS-232 interface for the Ionisation chamber\u003c\/li\u003e\n\u003cli\u003e1x USB interface for the optionally label printer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eUpdate to IBC-Nuclear Medicine and IBC-GMP Radiopharmacy\u003c\/h3\u003e\n\u003cp\u003eIBC-LITE can be updated to the software versions to manage activity in Nuclear Medicine and Radiopharmacy:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIBC-Nuclear Medicine and IBC-GMP Radiopharmacy\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.comecer.com\/nuclear-medicine\/radiochemistry-pet-cyclotron-conventional-nuclear-medicine\/radioactivity-measurement-systems\/ibc-nuclear-medicine-management-sysstem\/\" title=\"IBC Nuclear Medicine – Management System\"\u003eIBC-Nuclear Medicine\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eis a client-server based software environment to manage the daily routines in a Nuclear Medicine department. The software guarantees full traceability from ordering stock to injection of the patient dose. The software also offers the functionality to implement user definable protocols for a guided and controlled workflow to standardise the preparation process from stock to patient dose.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.comecer.com\/nuclear-medicine\/radiochemistry-pet-cyclotron-conventional-nuclear-medicine\/radioactivity-measurement-systems\/ibc-pro-hotlab-management-system\/\" title=\"IBC-GMP Radiopharmacy Management System\"\u003eIBC-GMP Radiopharmacy\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eis a state-of-the-art solution based on client\/server to manage the daily routine in radiopharmaceutical production centres that require “GMP” traceability. In these centres, the IBC-GMP Radiopharmacy management system offers a high level of integrated automation to standardise processes. In Radiopharmacies, the software supports order management, preparation and dispatch of ready-made multi-dose vials and\/or syringes. The software guarantees full traceability from ordering stock to the end product.\u003c\/p\u003e\n\u003cp\u003eToday’s GMP guidelines dictate that all processes need to be reported, validated and justified. Thanks to IBC-GMP Radiopharmacy, the highest level of GMP compliance can be integrated.\u003c\/p\u003e","brand":"Comecer","offers":[{"title":"Default Title","offer_id":46258640486540,"sku":null,"price":10000.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1750\/9895\/files\/IBC-Dose-Calibrator-780x751.png?v=1770599087","url":"https:\/\/www.globalmedicalsolutions.com.au\/products\/ibc-dose-calibrator","provider":"GMS Australia Pty Ltd","version":"1.0","type":"link"}