5130-3216-USED
As a combination of the popular CRC®-25R Dose Calibrator and the CAPRAC®-R Well Counter, the CRC®-25W dose calibrator provides advanced features with the speed and accuracy you need to measure activity and prepare doses. Its ion chamber is one of Capintec's time-tested, high pressure well designs capable of measuring a dose as high as 6 Ci (250 GBq) of Tc 99m with high accuracy. The CRC®-25W also features chamber plug-and-play capability.
OVERVIEW
For wipe testing, the CRC®-25W allows the user to define specific counting procedures (protocols) with trigger levels for work, patient, unrestricted areas and sealed source leak tests. The CRC®-25W also performs counting functions for wipe
tests in as little as 6 seconds at activities as low as 1 nCi. Low activities are measured with a drilled well high sensitivity Sodium Iodide (NaI) detector. The 6-channel pulse-height analyzer also provides the user with pulse amplitude discrimination, which can be used to help with radionuclide isotope identification. The chamber and counter of the CRC®-25W are combined in a menu driven, push-button interface that is easy to learn and use. Hardwired microchip control eliminates analog switches and dials, while improving measurement response time.
FEATURES
SPECIFICATIONS
Well Detector
• Type: Sodium Iodide (NaI) drilled-well crystal detector
• Energy Discrimination: Fixed range MCA, channel windows are
15-100, 100-200, 200-400, 400-660, 660-800 and >800 keV
• Warning Trigger Levels: User-definable
• Tests: Daily test by standard sources (Cs-137 or Ba-133), data
and program memory configuration
Ionization Chamber
• Type: Thin wall, deep well, high pressure
• Measurement: Auto ranging
• Activity Range: Up to 6 Ci (250 GBq)
• Resolution: .001 mBq (.01 μCi)
• Response Time: Within 2 sec., for low activity sample, 4 to 16
sec. (user selectable)
• Tests: Daily tests include Auto Zero, Background Adjustment,
Voltage Test, Data Check, Accuracy and Constancy
Display Screen
• Type: Dot matrix liquid crystal display
• Bq/Ci Reading: User selectable or fixed
• Calibrator Values: Selected radionuclide,calibration number,
measured activity and display units (Bq/Ci)
• Counter Values: Wipe and lab test results
Electrometer
• Accuracy: Better than ± 2%
• Linearity: Within ± 2%
CRC-25W Dose Calibrator ®
Nuclide Data
• Nuclide Setting Keys: 8 pre-set, 5 user selectable
• Calibration # Key: Calibration # Keys for Over 200 nuclides
• System Memory: Over 80 nuclides (w/cal number and half-life)
Standard Source Data
• System Memory: Co-57, Co-60, Ba-133, Cs-137, Ra-226 standard sources
Molybdenum-99 Assay
• Methods: CAPMAC® & canisters
• Measured Values: Mo-99 elution, Tc-99m,Tc-99m/Mo-99 ratio
PC Port
• Interface: RS-232C and USB port
• Compatibility: Standard nuclear medicine management systems
Printer Port
• RS-232 & USB
Power Requirements
• 100-240 VAC (50/60 Hz) 100 MA
Tests
• Diagnostics: Full test of program, system memories
Cable
• Printer (Optional): 1.8m (6ft)
DIMENSIONS
Console Dimensions
$8,331.00 $9,846.00
The new Capintec CRC®-55tPET Dose Calibrator gives you the ultimate features in the industry's finest package. The CRC®-55tPET Dose Calibrator is designed to meet the... View full product details
Provides the speed and accuracy you need to measure and prepare doses with the reliability and performance you expect from Capintec. The new Capintec CRC®-55tR... View full product details
The new Capintec CRC®-55tR Dose Calibrator provides the speed and accuracy you need to measure and prepare doses with the reliability and performance you expect... View full product details
The CRC®-77tHR’s performance and reliability have been designed to meet the unique and demanding needs of the high-activity isotope manufacturing and radiopharmaceutical production environments. OVERVIEW... View full product details
Sign up to get the latest on sales, new releases and more …
© 2024 GMS Australia Pty Ltd.
PRODUCTS NOT AVAILABLE FOR PURCHASE BY THE GENERAL PUBLIC .ALWAYS READ THE LABEL AND FOLLOW THE DIRECTIONS FOR USE
Powered by Shopify